K. Shimizu, K. Hakamata, T. Sakai, H. Yamauchi, H. Uchida, M. Hirayanagi, S. Nakamura, F. Nishikido, E. Yoshida, M. Suga, T. Obata, T. Yamaya
{"title":"用于MRI兼容应用的多像素光子计数器模块","authors":"K. Shimizu, K. Hakamata, T. Sakai, H. Yamauchi, H. Uchida, M. Hirayanagi, S. Nakamura, F. Nishikido, E. Yoshida, M. Suga, T. Obata, T. Yamaya","doi":"10.1109/NSSMIC.2015.7582021","DOIUrl":null,"url":null,"abstract":"A new detector for PET using multi-pixel photon counters (MPPCs) was developed for MRI compatible applications. This module has an 8 × 8 MPPC array, each segment has a 3 mm × 3 mm active area, and the pitch of the array is 4.1 mm in both directions. A temperature sensor is attached to the back of the array for temperature compensation. The MPPC array is connected to the front-end circuit with a detachable flexible printed circuit cable (FPC), which provides flexibility for detector arrangement. The front-end circuit consists of preamplifiers, a register network, buffer amplifiers, a built-in high voltage (HV) unit, and an embedded microprocessor unit. The HV unit is a down-regulator and requires an external HV supply. The preamplifier also has a sum output, which can be used for timing pick-off and energy discrimination. With LYSOs, the timing performance was evaluated using flexible printed cables of two different lengths. Set in a copper shield box, energy spectra and flood images were evaluated with a 3T-MRI Very little interference was observed during simultaneous MRI measurements.","PeriodicalId":106811,"journal":{"name":"2015 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Multi-pixel photon counter module for MRI compatible application\",\"authors\":\"K. Shimizu, K. Hakamata, T. Sakai, H. Yamauchi, H. Uchida, M. Hirayanagi, S. Nakamura, F. Nishikido, E. Yoshida, M. Suga, T. Obata, T. Yamaya\",\"doi\":\"10.1109/NSSMIC.2015.7582021\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A new detector for PET using multi-pixel photon counters (MPPCs) was developed for MRI compatible applications. This module has an 8 × 8 MPPC array, each segment has a 3 mm × 3 mm active area, and the pitch of the array is 4.1 mm in both directions. A temperature sensor is attached to the back of the array for temperature compensation. The MPPC array is connected to the front-end circuit with a detachable flexible printed circuit cable (FPC), which provides flexibility for detector arrangement. The front-end circuit consists of preamplifiers, a register network, buffer amplifiers, a built-in high voltage (HV) unit, and an embedded microprocessor unit. The HV unit is a down-regulator and requires an external HV supply. The preamplifier also has a sum output, which can be used for timing pick-off and energy discrimination. With LYSOs, the timing performance was evaluated using flexible printed cables of two different lengths. Set in a copper shield box, energy spectra and flood images were evaluated with a 3T-MRI Very little interference was observed during simultaneous MRI measurements.\",\"PeriodicalId\":106811,\"journal\":{\"name\":\"2015 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)\",\"volume\":\"24 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.2015.7582021\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2015.7582021","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Multi-pixel photon counter module for MRI compatible application
A new detector for PET using multi-pixel photon counters (MPPCs) was developed for MRI compatible applications. This module has an 8 × 8 MPPC array, each segment has a 3 mm × 3 mm active area, and the pitch of the array is 4.1 mm in both directions. A temperature sensor is attached to the back of the array for temperature compensation. The MPPC array is connected to the front-end circuit with a detachable flexible printed circuit cable (FPC), which provides flexibility for detector arrangement. The front-end circuit consists of preamplifiers, a register network, buffer amplifiers, a built-in high voltage (HV) unit, and an embedded microprocessor unit. The HV unit is a down-regulator and requires an external HV supply. The preamplifier also has a sum output, which can be used for timing pick-off and energy discrimination. With LYSOs, the timing performance was evaluated using flexible printed cables of two different lengths. Set in a copper shield box, energy spectra and flood images were evaluated with a 3T-MRI Very little interference was observed during simultaneous MRI measurements.