屏蔽飞机布线电容验证的重要性

J. R. Stone
{"title":"屏蔽飞机布线电容验证的重要性","authors":"J. R. Stone","doi":"10.1109/AUTEST.1992.270083","DOIUrl":null,"url":null,"abstract":"The need to advance wiring analyzers with the ability to analyze the interconnects now used in modern aircraft is discussed. In particular, twisted and shielded cabling is considered that is used to provide protection against electromagnetic interference (EMI), nuclear-induced electromagnetic pulses (ENPs), and high-speed data buses such as MIL-STD-1553B. Also discussed are common failures of shielded and twisted cables and methods of locating the faults. The method discussed in detail is the isolation of these faults by using a highly accurate capacitance comparator along with software to compensate for system and adaptor cable capacitance. Real-world capacitance measurements and the methods used to determine system capacitance tare with grounded and ungrounded systems are discussed. With an accurate system tare, the physical location of the actual defect can be determined.<<ETX>>","PeriodicalId":273287,"journal":{"name":"Conference Record AUTOTESTCON '92: The IEEE Systems Readiness Technology Conference","volume":"77 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Shielded aircraft cabling importance of verifying capacitance\",\"authors\":\"J. R. Stone\",\"doi\":\"10.1109/AUTEST.1992.270083\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The need to advance wiring analyzers with the ability to analyze the interconnects now used in modern aircraft is discussed. In particular, twisted and shielded cabling is considered that is used to provide protection against electromagnetic interference (EMI), nuclear-induced electromagnetic pulses (ENPs), and high-speed data buses such as MIL-STD-1553B. Also discussed are common failures of shielded and twisted cables and methods of locating the faults. The method discussed in detail is the isolation of these faults by using a highly accurate capacitance comparator along with software to compensate for system and adaptor cable capacitance. Real-world capacitance measurements and the methods used to determine system capacitance tare with grounded and ungrounded systems are discussed. With an accurate system tare, the physical location of the actual defect can be determined.<<ETX>>\",\"PeriodicalId\":273287,\"journal\":{\"name\":\"Conference Record AUTOTESTCON '92: The IEEE Systems Readiness Technology Conference\",\"volume\":\"77 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record AUTOTESTCON '92: The IEEE Systems Readiness Technology Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/AUTEST.1992.270083\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record AUTOTESTCON '92: The IEEE Systems Readiness Technology Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AUTEST.1992.270083","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

讨论了在现代飞机上使用的接线分析仪的发展需要,使其具备分析互连的能力。特别是,考虑到用于提供电磁干扰(EMI),核感应电磁脉冲(ENPs)和高速数据总线(如MIL-STD-1553B)保护的双绞线和屏蔽电缆。讨论了屏蔽电缆和绞合电缆的常见故障及故障定位方法。详细讨论的方法是通过使用高精度电容比较器以及软件来补偿系统和适配器电缆电容来隔离这些故障。讨论了实际电容测量和确定接地和不接地系统电容的方法。有了准确的系统数据,就可以确定实际缺陷的物理位置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Shielded aircraft cabling importance of verifying capacitance
The need to advance wiring analyzers with the ability to analyze the interconnects now used in modern aircraft is discussed. In particular, twisted and shielded cabling is considered that is used to provide protection against electromagnetic interference (EMI), nuclear-induced electromagnetic pulses (ENPs), and high-speed data buses such as MIL-STD-1553B. Also discussed are common failures of shielded and twisted cables and methods of locating the faults. The method discussed in detail is the isolation of these faults by using a highly accurate capacitance comparator along with software to compensate for system and adaptor cable capacitance. Real-world capacitance measurements and the methods used to determine system capacitance tare with grounded and ungrounded systems are discussed. With an accurate system tare, the physical location of the actual defect can be determined.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信