{"title":"高性能纤维-钢筋混凝土耦合梁耦合墙试验研究","authors":"R. Lequesne, G. Parra-Montesinos, J. Wight","doi":"10.14359/51663288","DOIUrl":null,"url":null,"abstract":"Synopsis: Results from the test of a large-scale coupled-wall specimen consisting of two T-shaped reinforced concrete structural walls joined at four levels by precast coupling beams are presented. Each coupling beam had a span length-to-depth ratio ( / n h ) of 1.7, and was designed to carry a shear stress of","PeriodicalId":310990,"journal":{"name":"SP-265: Thomas T.C. Hsu Symposium: Shear and Torsion in Concrete Structures","volume":"35 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Test of a Coupled Wall with High-Performance Fiber-Reinforced Concrete Coupling Beams\",\"authors\":\"R. Lequesne, G. Parra-Montesinos, J. Wight\",\"doi\":\"10.14359/51663288\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Synopsis: Results from the test of a large-scale coupled-wall specimen consisting of two T-shaped reinforced concrete structural walls joined at four levels by precast coupling beams are presented. Each coupling beam had a span length-to-depth ratio ( / n h ) of 1.7, and was designed to carry a shear stress of\",\"PeriodicalId\":310990,\"journal\":{\"name\":\"SP-265: Thomas T.C. Hsu Symposium: Shear and Torsion in Concrete Structures\",\"volume\":\"35 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"SP-265: Thomas T.C. Hsu Symposium: Shear and Torsion in Concrete Structures\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14359/51663288\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"SP-265: Thomas T.C. Hsu Symposium: Shear and Torsion in Concrete Structures","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14359/51663288","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8
摘要
摘要:本文介绍了由预制连接梁在四层连接的两个t形钢筋混凝土结构墙组成的大型连接墙试件的试验结果。每根连接梁的跨长深比(/ n h)为1.7,设计承受剪应力为
Test of a Coupled Wall with High-Performance Fiber-Reinforced Concrete Coupling Beams
Synopsis: Results from the test of a large-scale coupled-wall specimen consisting of two T-shaped reinforced concrete structural walls joined at four levels by precast coupling beams are presented. Each coupling beam had a span length-to-depth ratio ( / n h ) of 1.7, and was designed to carry a shear stress of