无功最优规划的系统灵敏度方法

W. Refaey, A. Ghandakly, M. Azzoz, I. Khalifa, Omar H. Abdalla
{"title":"无功最优规划的系统灵敏度方法","authors":"W. Refaey, A. Ghandakly, M. Azzoz, I. Khalifa, Omar H. Abdalla","doi":"10.1109/NAPS.1990.151381","DOIUrl":null,"url":null,"abstract":"A systematic procedure is developed to locate and minimize the number of reactive power devices in power systems based on a set of indices and the sensitivity matrix. A definition of the bus voltage performance index (VPI) is proposed for optimal reactive power planning. It is equal to the root mean square value of the corresponding column of the sensitivity matrix. The VPIs in previous work depend on the norms which can be defined in nonunique ways. In the proposed technique, the three indices are given different weights depending on their values. The load buses are also ordered on the basis of their values depending on the total weights at each bus for the three indices. This ordering of load buses as well as the sensitivity matrix is then used to determine the optimal location and number of reactive power devices required in the system.<<ETX>>","PeriodicalId":330083,"journal":{"name":"Proceedings of the Twenty-Second Annual North American Power Symposium","volume":"132 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1990-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"A systematic sensitivity approach for optimal reactive power planning\",\"authors\":\"W. Refaey, A. Ghandakly, M. Azzoz, I. Khalifa, Omar H. Abdalla\",\"doi\":\"10.1109/NAPS.1990.151381\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A systematic procedure is developed to locate and minimize the number of reactive power devices in power systems based on a set of indices and the sensitivity matrix. A definition of the bus voltage performance index (VPI) is proposed for optimal reactive power planning. It is equal to the root mean square value of the corresponding column of the sensitivity matrix. The VPIs in previous work depend on the norms which can be defined in nonunique ways. In the proposed technique, the three indices are given different weights depending on their values. The load buses are also ordered on the basis of their values depending on the total weights at each bus for the three indices. This ordering of load buses as well as the sensitivity matrix is then used to determine the optimal location and number of reactive power devices required in the system.<<ETX>>\",\"PeriodicalId\":330083,\"journal\":{\"name\":\"Proceedings of the Twenty-Second Annual North American Power Symposium\",\"volume\":\"132 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-10-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Twenty-Second Annual North American Power Symposium\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NAPS.1990.151381\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Twenty-Second Annual North American Power Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NAPS.1990.151381","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

基于一组指标和灵敏度矩阵,提出了一套定位和最小化电力系统无功装置数量的系统方法。提出了用于最优无功规划的母线电压性能指标(VPI)的定义。它等于灵敏度矩阵对应列的均方根值。以前工作中的vpi依赖于可以用非唯一方式定义的规范。在该技术中,三个指标根据其值被赋予不同的权重。负载总线也根据它们的值排序,这取决于三个指标在每个总线上的总权重。负载母线的排序以及灵敏度矩阵然后用于确定系统中所需无功设备的最佳位置和数量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A systematic sensitivity approach for optimal reactive power planning
A systematic procedure is developed to locate and minimize the number of reactive power devices in power systems based on a set of indices and the sensitivity matrix. A definition of the bus voltage performance index (VPI) is proposed for optimal reactive power planning. It is equal to the root mean square value of the corresponding column of the sensitivity matrix. The VPIs in previous work depend on the norms which can be defined in nonunique ways. In the proposed technique, the three indices are given different weights depending on their values. The load buses are also ordered on the basis of their values depending on the total weights at each bus for the three indices. This ordering of load buses as well as the sensitivity matrix is then used to determine the optimal location and number of reactive power devices required in the system.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信