A. Hoelke, H. T. Henderson, F. Gerner, M. Kazmierczak
{"title":"微机械循环热管的传热能力分析","authors":"A. Hoelke, H. T. Henderson, F. Gerner, M. Kazmierczak","doi":"10.1115/imece1999-1062","DOIUrl":null,"url":null,"abstract":"\n For on-chip electronic cooling, a micromachined silicon LHP (Loop Heat Pipe) is being developed, with a Coherent Porous Silicon (CPS) wick as the central part. The present work is a lumped-element network analysis of the overall heat removal performance of such a device. A heat flux of more than 100 W/cm2 is predicted for a micromachined baseline LHP. Moreover, this system-level model shows that a higher performance could be achieved by optimizing the vapor-removing duct. This would be possible without severe microfabrication challenges. The predicted performance of an optimized LHP with reduced turbulent flow losses in the evaporator exceeds 1000 W/cm2.","PeriodicalId":306962,"journal":{"name":"Heat Transfer: Volume 3","volume":"60 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-11-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"20","resultStr":"{\"title\":\"Analysis of the Heat Transfer Capacity of a Micromachined Loop Heat Pipe\",\"authors\":\"A. Hoelke, H. T. Henderson, F. Gerner, M. Kazmierczak\",\"doi\":\"10.1115/imece1999-1062\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n For on-chip electronic cooling, a micromachined silicon LHP (Loop Heat Pipe) is being developed, with a Coherent Porous Silicon (CPS) wick as the central part. The present work is a lumped-element network analysis of the overall heat removal performance of such a device. A heat flux of more than 100 W/cm2 is predicted for a micromachined baseline LHP. Moreover, this system-level model shows that a higher performance could be achieved by optimizing the vapor-removing duct. This would be possible without severe microfabrication challenges. The predicted performance of an optimized LHP with reduced turbulent flow losses in the evaporator exceeds 1000 W/cm2.\",\"PeriodicalId\":306962,\"journal\":{\"name\":\"Heat Transfer: Volume 3\",\"volume\":\"60 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-11-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"20\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Heat Transfer: Volume 3\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/imece1999-1062\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Heat Transfer: Volume 3","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/imece1999-1062","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Analysis of the Heat Transfer Capacity of a Micromachined Loop Heat Pipe
For on-chip electronic cooling, a micromachined silicon LHP (Loop Heat Pipe) is being developed, with a Coherent Porous Silicon (CPS) wick as the central part. The present work is a lumped-element network analysis of the overall heat removal performance of such a device. A heat flux of more than 100 W/cm2 is predicted for a micromachined baseline LHP. Moreover, this system-level model shows that a higher performance could be achieved by optimizing the vapor-removing duct. This would be possible without severe microfabrication challenges. The predicted performance of an optimized LHP with reduced turbulent flow losses in the evaporator exceeds 1000 W/cm2.