{"title":"用x射线荧光光谱仪快速测定冷凝器冷却水中铜的含量","authors":"Z. Hua","doi":"10.1109/CICED50259.2021.9556650","DOIUrl":null,"url":null,"abstract":"In this paper, X-ray fluorescence spectrometer (XRFS) were tried to achieve rapid determination of copper content in condenser cooling water. Three mathematical models based on untransformed and ln-transformed data were discussed to select the final regression equation of new method. Numbers of cooling water samples from 2019 to 2020 were subjected to both AAS and XRFS. An acceptable correlation coefficient with R2=0.8305 was achieved based on the two datasets, which shows reliability and accuracy in rapid determination of copper content in condenser cooling water.","PeriodicalId":221387,"journal":{"name":"2021 China International Conference on Electricity Distribution (CICED)","volume":"49 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Rapid Determination of Copper Content in Condenser Cooling Water by X-ray Fluorescence Spectrometer\",\"authors\":\"Z. Hua\",\"doi\":\"10.1109/CICED50259.2021.9556650\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, X-ray fluorescence spectrometer (XRFS) were tried to achieve rapid determination of copper content in condenser cooling water. Three mathematical models based on untransformed and ln-transformed data were discussed to select the final regression equation of new method. Numbers of cooling water samples from 2019 to 2020 were subjected to both AAS and XRFS. An acceptable correlation coefficient with R2=0.8305 was achieved based on the two datasets, which shows reliability and accuracy in rapid determination of copper content in condenser cooling water.\",\"PeriodicalId\":221387,\"journal\":{\"name\":\"2021 China International Conference on Electricity Distribution (CICED)\",\"volume\":\"49 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-04-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 China International Conference on Electricity Distribution (CICED)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CICED50259.2021.9556650\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 China International Conference on Electricity Distribution (CICED)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CICED50259.2021.9556650","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Rapid Determination of Copper Content in Condenser Cooling Water by X-ray Fluorescence Spectrometer
In this paper, X-ray fluorescence spectrometer (XRFS) were tried to achieve rapid determination of copper content in condenser cooling water. Three mathematical models based on untransformed and ln-transformed data were discussed to select the final regression equation of new method. Numbers of cooling water samples from 2019 to 2020 were subjected to both AAS and XRFS. An acceptable correlation coefficient with R2=0.8305 was achieved based on the two datasets, which shows reliability and accuracy in rapid determination of copper content in condenser cooling water.