处理器电源管理的自适应管道深度控制

A. Efthymiou, J. Garside
{"title":"处理器电源管理的自适应管道深度控制","authors":"A. Efthymiou, J. Garside","doi":"10.1109/ICCD.2002.1106812","DOIUrl":null,"url":null,"abstract":"A method of managing the power consumption of an embedded, single-issue processor by controlling its pipeline depth is proposed. The execution time will be increased but, if the method is applied to applications with slack time, the user-perceived performance may not be degraded Two techniques are shown using an existing asynchronous processor as a starting point. The first method controls the pipeline occupancy using a token mechanism, the second enables adjacent pipeline stages to be merged, by making the latches between them 'permanently' transparent. An energy reduction of up to 16% is measured, using a collection of five benchmarks.","PeriodicalId":164768,"journal":{"name":"Proceedings. IEEE International Conference on Computer Design: VLSI in Computers and Processors","volume":"57 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"54","resultStr":"{\"title\":\"Adaptive pipeline depth control for processor power-management\",\"authors\":\"A. Efthymiou, J. Garside\",\"doi\":\"10.1109/ICCD.2002.1106812\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A method of managing the power consumption of an embedded, single-issue processor by controlling its pipeline depth is proposed. The execution time will be increased but, if the method is applied to applications with slack time, the user-perceived performance may not be degraded Two techniques are shown using an existing asynchronous processor as a starting point. The first method controls the pipeline occupancy using a token mechanism, the second enables adjacent pipeline stages to be merged, by making the latches between them 'permanently' transparent. An energy reduction of up to 16% is measured, using a collection of five benchmarks.\",\"PeriodicalId\":164768,\"journal\":{\"name\":\"Proceedings. IEEE International Conference on Computer Design: VLSI in Computers and Processors\",\"volume\":\"57 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"54\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings. IEEE International Conference on Computer Design: VLSI in Computers and Processors\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICCD.2002.1106812\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings. IEEE International Conference on Computer Design: VLSI in Computers and Processors","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCD.2002.1106812","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 54

摘要

提出了一种通过控制流水线深度来管理嵌入式单问题处理器功耗的方法。执行时间会增加,但是,如果将该方法应用于有空闲时间的应用程序,则用户感知的性能可能不会降低。第一种方法使用令牌机制控制管道占用,第二种方法通过使它们之间的锁存“永久”透明,使相邻的管道阶段能够合并。使用五个基准的集合,测量了高达16%的能源减少。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Adaptive pipeline depth control for processor power-management
A method of managing the power consumption of an embedded, single-issue processor by controlling its pipeline depth is proposed. The execution time will be increased but, if the method is applied to applications with slack time, the user-perceived performance may not be degraded Two techniques are shown using an existing asynchronous processor as a starting point. The first method controls the pipeline occupancy using a token mechanism, the second enables adjacent pipeline stages to be merged, by making the latches between them 'permanently' transparent. An energy reduction of up to 16% is measured, using a collection of five benchmarks.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.30
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信