下一线路相间故障继电点测量阻抗

H. Shateri, S. Jamali
{"title":"下一线路相间故障继电点测量阻抗","authors":"H. Shateri, S. Jamali","doi":"10.1109/UPEC.2008.4651508","DOIUrl":null,"url":null,"abstract":"Distance relays are one of the mostly used protective devices in the transmission systems. These relays are used as the main, First zone and a part of second zone, and the backup, the rest of second zone and third zone, protective devices. Fault resistance is a source of error for distance relays in the form of the measured impedance deviation from its actual value. This paper investigates the measured impedance by distance relays for the faults on the protected and next line in the case of inter phase, phase to phase and three phase, faults by means of presenting measured impedance and investigating its variation duo the changes in the power system conditions.","PeriodicalId":287461,"journal":{"name":"2008 43rd International Universities Power Engineering Conference","volume":"79 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-12-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Measured impedance at relaying point for inter phase faults on next line\",\"authors\":\"H. Shateri, S. Jamali\",\"doi\":\"10.1109/UPEC.2008.4651508\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Distance relays are one of the mostly used protective devices in the transmission systems. These relays are used as the main, First zone and a part of second zone, and the backup, the rest of second zone and third zone, protective devices. Fault resistance is a source of error for distance relays in the form of the measured impedance deviation from its actual value. This paper investigates the measured impedance by distance relays for the faults on the protected and next line in the case of inter phase, phase to phase and three phase, faults by means of presenting measured impedance and investigating its variation duo the changes in the power system conditions.\",\"PeriodicalId\":287461,\"journal\":{\"name\":\"2008 43rd International Universities Power Engineering Conference\",\"volume\":\"79 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-12-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 43rd International Universities Power Engineering Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/UPEC.2008.4651508\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 43rd International Universities Power Engineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/UPEC.2008.4651508","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

距离继电器是输电系统中最常用的保护装置之一。这些继电器被用作主要的、第一区域和第二区域的一部分,以及备用的、第二区域的其余部分和第三区域的保护装置。故障电阻是距离继电器的误差来源,其形式是测量阻抗与其实际值的偏差。本文通过给出测量阻抗并考察其随电力系统条件变化的变化情况,研究了距离继电器在保护线和旁线发生相间、相间和三相故障时的测量阻抗。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Measured impedance at relaying point for inter phase faults on next line
Distance relays are one of the mostly used protective devices in the transmission systems. These relays are used as the main, First zone and a part of second zone, and the backup, the rest of second zone and third zone, protective devices. Fault resistance is a source of error for distance relays in the form of the measured impedance deviation from its actual value. This paper investigates the measured impedance by distance relays for the faults on the protected and next line in the case of inter phase, phase to phase and three phase, faults by means of presenting measured impedance and investigating its variation duo the changes in the power system conditions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信