Young-Gui Lee, Hyewon Lee, Yeon-Hee Kim, T. Zheng, Y. Kang
{"title":"基于时域有功和无功功率的微电网孤岛检测","authors":"Young-Gui Lee, Hyewon Lee, Yeon-Hee Kim, T. Zheng, Y. Kang","doi":"10.1109/APAP.2011.6180681","DOIUrl":null,"url":null,"abstract":"The micro-grid (MG) should supply the power to its loads continuously after disconnecting the circuit breakers between the distribution networks and the MG, which is called with islanding operation. In this case, the detection of islanding is a very important issue for the MG because the threshold values for the protection relays in the MG should be changed depending on whether the MG is connected to the grid or not. This paper proposes an islanding detection algorithm for the MG based on the active and reactive power delivered from the MG to dedicated line in the time domain. The performance of the proposed algorithm is verified under various scenarios including islanding conditions and fault conditions using the PSCAD/EMTDC simulator. The results indicate that the proposed algorithm can detect the power islanding under various islanding conditions for the different outputs of the MG, and does not mal-operate under various fault conditions varying the fault positions, irrespectively of the frequency deviation and the transient components.","PeriodicalId":435652,"journal":{"name":"2011 International Conference on Advanced Power System Automation and Protection","volume":"138 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Islanding detection for a micro-grid based on the active and reactive power in the time domain\",\"authors\":\"Young-Gui Lee, Hyewon Lee, Yeon-Hee Kim, T. Zheng, Y. Kang\",\"doi\":\"10.1109/APAP.2011.6180681\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The micro-grid (MG) should supply the power to its loads continuously after disconnecting the circuit breakers between the distribution networks and the MG, which is called with islanding operation. In this case, the detection of islanding is a very important issue for the MG because the threshold values for the protection relays in the MG should be changed depending on whether the MG is connected to the grid or not. This paper proposes an islanding detection algorithm for the MG based on the active and reactive power delivered from the MG to dedicated line in the time domain. The performance of the proposed algorithm is verified under various scenarios including islanding conditions and fault conditions using the PSCAD/EMTDC simulator. The results indicate that the proposed algorithm can detect the power islanding under various islanding conditions for the different outputs of the MG, and does not mal-operate under various fault conditions varying the fault positions, irrespectively of the frequency deviation and the transient components.\",\"PeriodicalId\":435652,\"journal\":{\"name\":\"2011 International Conference on Advanced Power System Automation and Protection\",\"volume\":\"138 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 International Conference on Advanced Power System Automation and Protection\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APAP.2011.6180681\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Advanced Power System Automation and Protection","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APAP.2011.6180681","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Islanding detection for a micro-grid based on the active and reactive power in the time domain
The micro-grid (MG) should supply the power to its loads continuously after disconnecting the circuit breakers between the distribution networks and the MG, which is called with islanding operation. In this case, the detection of islanding is a very important issue for the MG because the threshold values for the protection relays in the MG should be changed depending on whether the MG is connected to the grid or not. This paper proposes an islanding detection algorithm for the MG based on the active and reactive power delivered from the MG to dedicated line in the time domain. The performance of the proposed algorithm is verified under various scenarios including islanding conditions and fault conditions using the PSCAD/EMTDC simulator. The results indicate that the proposed algorithm can detect the power islanding under various islanding conditions for the different outputs of the MG, and does not mal-operate under various fault conditions varying the fault positions, irrespectively of the frequency deviation and the transient components.