一种用于三相微电网动态负载均衡的新型有源相位路由器

K. Narayanan, L. Umanand
{"title":"一种用于三相微电网动态负载均衡的新型有源相位路由器","authors":"K. Narayanan, L. Umanand","doi":"10.1109/APPEEC.2017.8308922","DOIUrl":null,"url":null,"abstract":"This paper presents a novel active phase router for dynamic load balancing in a three-phase system. Uneven distribution of single phase loads may result in current unbalances among the three-phase lines. The current unbalances in a three-phase system results in increased power losses due to presence of the negative sequence currents. The loading capacity of the distribution transformers and the three phase lines in the microgrid also gets limited below their nominal ratings. The proposed phase router can be used to mitigate the effect of unbalance caused by single phase loads in the three phase microgrids. The phase router uses a set of bidirectional semiconductor switches for routing the single-phase loads to the appropriate three phase lines with the objective of minimizing unbalance in the three phase lines. Expressions have been derived to obtain optimal switching instances with minimum transients for different types of loads. The proposed phase router has been simulated and experimentally verified through a prototype.","PeriodicalId":247669,"journal":{"name":"2017 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"A novel active phase router for dynamic load balancing in a three phase microgrid\",\"authors\":\"K. Narayanan, L. Umanand\",\"doi\":\"10.1109/APPEEC.2017.8308922\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a novel active phase router for dynamic load balancing in a three-phase system. Uneven distribution of single phase loads may result in current unbalances among the three-phase lines. The current unbalances in a three-phase system results in increased power losses due to presence of the negative sequence currents. The loading capacity of the distribution transformers and the three phase lines in the microgrid also gets limited below their nominal ratings. The proposed phase router can be used to mitigate the effect of unbalance caused by single phase loads in the three phase microgrids. The phase router uses a set of bidirectional semiconductor switches for routing the single-phase loads to the appropriate three phase lines with the objective of minimizing unbalance in the three phase lines. Expressions have been derived to obtain optimal switching instances with minimum transients for different types of loads. The proposed phase router has been simulated and experimentally verified through a prototype.\",\"PeriodicalId\":247669,\"journal\":{\"name\":\"2017 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)\",\"volume\":\"24 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APPEEC.2017.8308922\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APPEEC.2017.8308922","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

提出了一种用于三相系统动态负载均衡的新型有源相位路由器。单相负载分布不均匀会导致三相线路电流不平衡。由于负序电流的存在,三相系统中的电流不平衡导致功率损耗增加。微电网中配电变压器和三相线路的负载能力也被限制在其标称额定值以下。所提出的相位路由器可用于缓解三相微电网中单相负载不平衡的影响。相位路由器使用一组双向半导体开关将单相负载路由到适当的三相线路上,目的是尽量减少三相线路的不平衡。对不同类型的负载,导出了具有最小暂态的最优切换实例的表达式。通过样机对所提出的相位路由器进行了仿真和实验验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A novel active phase router for dynamic load balancing in a three phase microgrid
This paper presents a novel active phase router for dynamic load balancing in a three-phase system. Uneven distribution of single phase loads may result in current unbalances among the three-phase lines. The current unbalances in a three-phase system results in increased power losses due to presence of the negative sequence currents. The loading capacity of the distribution transformers and the three phase lines in the microgrid also gets limited below their nominal ratings. The proposed phase router can be used to mitigate the effect of unbalance caused by single phase loads in the three phase microgrids. The phase router uses a set of bidirectional semiconductor switches for routing the single-phase loads to the appropriate three phase lines with the objective of minimizing unbalance in the three phase lines. Expressions have been derived to obtain optimal switching instances with minimum transients for different types of loads. The proposed phase router has been simulated and experimentally verified through a prototype.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信