PWM逆变器实时数字反馈控制的五种不同方法的比较

A. Kawamura, T. Yokoyama
{"title":"PWM逆变器实时数字反馈控制的五种不同方法的比较","authors":"A. Kawamura, T. Yokoyama","doi":"10.1109/IAS.1990.152307","DOIUrl":null,"url":null,"abstract":"The five schemes are resistive-load-based deadbeat (DB) control, disturbance-observer-based DB control I. disturbance-observer-based DB control II, internal-model-principle-based pole placement, and digital proportional-integral (PI) control. The control schemes are applicable to single-phase and three-phase balanced-load inverter systems because the balanced three-phase system can be converted to two decoupled single phase systems. The modification of the control law from a single-phase to a three-phase system is explained. Simulations were performed in both systems, and experiments were carried out in the three-phase PWM inverter system. The disturbance-observer-based I and the digital PI control schemes yielded the best overall performance. The former is better in terms of total harmonic distortion for a nonlinear load, but the latter is based on a much simpler algorithm.<<ETX>>","PeriodicalId":185839,"journal":{"name":"Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting","volume":"274 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1990-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"57","resultStr":"{\"title\":\"Comparison of five different approaches for real time digital feedback control of PWM inverters\",\"authors\":\"A. Kawamura, T. Yokoyama\",\"doi\":\"10.1109/IAS.1990.152307\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The five schemes are resistive-load-based deadbeat (DB) control, disturbance-observer-based DB control I. disturbance-observer-based DB control II, internal-model-principle-based pole placement, and digital proportional-integral (PI) control. The control schemes are applicable to single-phase and three-phase balanced-load inverter systems because the balanced three-phase system can be converted to two decoupled single phase systems. The modification of the control law from a single-phase to a three-phase system is explained. Simulations were performed in both systems, and experiments were carried out in the three-phase PWM inverter system. The disturbance-observer-based I and the digital PI control schemes yielded the best overall performance. The former is better in terms of total harmonic distortion for a nonlinear load, but the latter is based on a much simpler algorithm.<<ETX>>\",\"PeriodicalId\":185839,\"journal\":{\"name\":\"Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting\",\"volume\":\"274 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"57\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IAS.1990.152307\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.1990.152307","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 57

摘要

这五种方案分别是基于电阻负载的无差beat (DB)控制、基于干扰观测器的DB控制i、基于干扰观测器的DB控制II、基于内部模型原理的极点放置和数字比例积分(PI)控制。该控制方案适用于单相和三相平衡负载逆变系统,因为平衡三相系统可以转换为两个解耦的单相系统。说明了从单相系统到三相系统控制律的修改。在两种系统中进行了仿真,并在三相PWM逆变系统中进行了实验。基于扰动观测器的I和数字PI控制方案获得了最佳的综合性能。对于非线性负载,前者在总谐波畸变方面表现较好,而后者基于更简单的算法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of five different approaches for real time digital feedback control of PWM inverters
The five schemes are resistive-load-based deadbeat (DB) control, disturbance-observer-based DB control I. disturbance-observer-based DB control II, internal-model-principle-based pole placement, and digital proportional-integral (PI) control. The control schemes are applicable to single-phase and three-phase balanced-load inverter systems because the balanced three-phase system can be converted to two decoupled single phase systems. The modification of the control law from a single-phase to a three-phase system is explained. Simulations were performed in both systems, and experiments were carried out in the three-phase PWM inverter system. The disturbance-observer-based I and the digital PI control schemes yielded the best overall performance. The former is better in terms of total harmonic distortion for a nonlinear load, but the latter is based on a much simpler algorithm.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信