{"title":"用于精确液位测量的FMCW雷达","authors":"O. Edvardsson","doi":"10.1109/EUMA.1979.332665","DOIUrl":null,"url":null,"abstract":"The system is intended for tank level measurements and is based on a single linear sweep. By the use of a coaxial cable as a reference and a special calculating process a good accuracy and noise immunity is obtained. The accuracy is typical 0,05 % or 5 mm over a 0-60 m range. One problem with the application is the discrimination of false echoes which is done by a narrow antenna beam, an amplitude threshold and a filter. The calculation and the filtering is insensitive to unlinearities.","PeriodicalId":128931,"journal":{"name":"1979 9th European Microwave Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1979-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":"{\"title\":\"An FMCW Radar for Accurate Level Measurements\",\"authors\":\"O. Edvardsson\",\"doi\":\"10.1109/EUMA.1979.332665\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The system is intended for tank level measurements and is based on a single linear sweep. By the use of a coaxial cable as a reference and a special calculating process a good accuracy and noise immunity is obtained. The accuracy is typical 0,05 % or 5 mm over a 0-60 m range. One problem with the application is the discrimination of false echoes which is done by a narrow antenna beam, an amplitude threshold and a filter. The calculation and the filtering is insensitive to unlinearities.\",\"PeriodicalId\":128931,\"journal\":{\"name\":\"1979 9th European Microwave Conference\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1979-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1979 9th European Microwave Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EUMA.1979.332665\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1979 9th European Microwave Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EUMA.1979.332665","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The system is intended for tank level measurements and is based on a single linear sweep. By the use of a coaxial cable as a reference and a special calculating process a good accuracy and noise immunity is obtained. The accuracy is typical 0,05 % or 5 mm over a 0-60 m range. One problem with the application is the discrimination of false echoes which is done by a narrow antenna beam, an amplitude threshold and a filter. The calculation and the filtering is insensitive to unlinearities.