A. Szymił, R. Krzyminiewski, B. Dobosz, A. Pajak, A. Szyszka, M. Ładzińska
{"title":"基于高信号分辨率的心血管系统脉冲波形分析","authors":"A. Szymił, R. Krzyminiewski, B. Dobosz, A. Pajak, A. Szyszka, M. Ładzińska","doi":"10.2478/CTB-2014-0075","DOIUrl":null,"url":null,"abstract":"Abstract The aim of this study was to carry out the FMD (flow - mediated dilatation) and NID (nitroglycerin-induced dilatation) tests in the case of patients with hypertension by using new measurement method - High Signal Resolution Pulse Wave (HSR PW). The paper presents new diagnostic method HSR PW which was used to evaluate the pulse wave in patients with arterial hypertension. HSR-PW is a method based on increasing the resolution of the pulse wave signal, recorded during a standard test using the Fourier Transform. The study involved twenty-four patients with hypertension and fifteen healthy people as a control group. The analysis showed that changes of the shape of the pulse wave in HSR PW took place in both groups conducting the FMD and NID tests. The HSR PW method proved to be more sensitive to changes in the body then the standard pulse oximeter and therefore may increase clinical practicability.","PeriodicalId":333495,"journal":{"name":"Current Topics in Biophysics","volume":"433 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Pulse Wave Shape Analysis of the Cardiovascular System Using High Signal Resolution\",\"authors\":\"A. Szymił, R. Krzyminiewski, B. Dobosz, A. Pajak, A. Szyszka, M. Ładzińska\",\"doi\":\"10.2478/CTB-2014-0075\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract The aim of this study was to carry out the FMD (flow - mediated dilatation) and NID (nitroglycerin-induced dilatation) tests in the case of patients with hypertension by using new measurement method - High Signal Resolution Pulse Wave (HSR PW). The paper presents new diagnostic method HSR PW which was used to evaluate the pulse wave in patients with arterial hypertension. HSR-PW is a method based on increasing the resolution of the pulse wave signal, recorded during a standard test using the Fourier Transform. The study involved twenty-four patients with hypertension and fifteen healthy people as a control group. The analysis showed that changes of the shape of the pulse wave in HSR PW took place in both groups conducting the FMD and NID tests. The HSR PW method proved to be more sensitive to changes in the body then the standard pulse oximeter and therefore may increase clinical practicability.\",\"PeriodicalId\":333495,\"journal\":{\"name\":\"Current Topics in Biophysics\",\"volume\":\"433 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current Topics in Biophysics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2478/CTB-2014-0075\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Topics in Biophysics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/CTB-2014-0075","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

摘要本研究采用新的测量方法-高信号分辨率脉冲波(HSR PW)对高血压患者进行血流介导扩张(FMD)和硝酸甘油诱导扩张(NID)试验。本文介绍了一种新的诊断方法——高磁共振PW,用于评价动脉性高血压患者的脉搏波。HSR-PW是一种基于提高脉冲波信号的分辨率的方法,在标准测试中使用傅里叶变换记录。这项研究包括24名高血压患者和15名健康人作为对照组。分析表明,在进行FMD和NID试验的两组中,高铁PW的脉冲波形状都发生了变化。HSR PW方法被证明比标准脉搏血氧仪对身体的变化更敏感,因此可以增加临床实用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Pulse Wave Shape Analysis of the Cardiovascular System Using High Signal Resolution
Abstract The aim of this study was to carry out the FMD (flow - mediated dilatation) and NID (nitroglycerin-induced dilatation) tests in the case of patients with hypertension by using new measurement method - High Signal Resolution Pulse Wave (HSR PW). The paper presents new diagnostic method HSR PW which was used to evaluate the pulse wave in patients with arterial hypertension. HSR-PW is a method based on increasing the resolution of the pulse wave signal, recorded during a standard test using the Fourier Transform. The study involved twenty-four patients with hypertension and fifteen healthy people as a control group. The analysis showed that changes of the shape of the pulse wave in HSR PW took place in both groups conducting the FMD and NID tests. The HSR PW method proved to be more sensitive to changes in the body then the standard pulse oximeter and therefore may increase clinical practicability.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信