Behrooz Taheri, S. A. Hosseini, Hossein Askarian‐Abyaneh, F. Razavi
{"title":"利用Internet协议版本4远程测试距离中继的新方法","authors":"Behrooz Taheri, S. A. Hosseini, Hossein Askarian‐Abyaneh, F. Razavi","doi":"10.1109/IPAPS.2019.8641918","DOIUrl":null,"url":null,"abstract":"The bulk of studies on power-system protection focus on fault detection algorithms in protective relays. However, a major part of protective relays problems come from their hidden failures. Hidden failures are not detected in the normal network state. They will be detected when an error occurs in a power grid where a relay malfunctions. This can make the power grid unstable. To prevent such an occurrence, protective relays need to be tested periodically. Such tests are very time-consuming and costly especially in remote substations. Based on the Internet Protocol Version 4 (IPv4), a new method is proposed in this paper for remote relay testing. This method allows a technician to test a relay remotely. In addition to low-level tests (such as shot test), the proposed method can carry out transient tests. The proposed method is implemented thoroughly on an AMT-105, a relay tester made by Vebko Amirkabir Company. Then the applicability of the proposed method was tested and analyzed completely using a distance relay of a real-life substation.","PeriodicalId":173653,"journal":{"name":"2019 International Conference on Protection and Automation of Power System (IPAPS)","volume":"23 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":"{\"title\":\"A New Method for Remote Testing Distance Relay Using Internet Protocol Version 4\",\"authors\":\"Behrooz Taheri, S. A. Hosseini, Hossein Askarian‐Abyaneh, F. Razavi\",\"doi\":\"10.1109/IPAPS.2019.8641918\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The bulk of studies on power-system protection focus on fault detection algorithms in protective relays. However, a major part of protective relays problems come from their hidden failures. Hidden failures are not detected in the normal network state. They will be detected when an error occurs in a power grid where a relay malfunctions. This can make the power grid unstable. To prevent such an occurrence, protective relays need to be tested periodically. Such tests are very time-consuming and costly especially in remote substations. Based on the Internet Protocol Version 4 (IPv4), a new method is proposed in this paper for remote relay testing. This method allows a technician to test a relay remotely. In addition to low-level tests (such as shot test), the proposed method can carry out transient tests. The proposed method is implemented thoroughly on an AMT-105, a relay tester made by Vebko Amirkabir Company. Then the applicability of the proposed method was tested and analyzed completely using a distance relay of a real-life substation.\",\"PeriodicalId\":173653,\"journal\":{\"name\":\"2019 International Conference on Protection and Automation of Power System (IPAPS)\",\"volume\":\"23 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"14\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 International Conference on Protection and Automation of Power System (IPAPS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IPAPS.2019.8641918\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International Conference on Protection and Automation of Power System (IPAPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPAPS.2019.8641918","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A New Method for Remote Testing Distance Relay Using Internet Protocol Version 4
The bulk of studies on power-system protection focus on fault detection algorithms in protective relays. However, a major part of protective relays problems come from their hidden failures. Hidden failures are not detected in the normal network state. They will be detected when an error occurs in a power grid where a relay malfunctions. This can make the power grid unstable. To prevent such an occurrence, protective relays need to be tested periodically. Such tests are very time-consuming and costly especially in remote substations. Based on the Internet Protocol Version 4 (IPv4), a new method is proposed in this paper for remote relay testing. This method allows a technician to test a relay remotely. In addition to low-level tests (such as shot test), the proposed method can carry out transient tests. The proposed method is implemented thoroughly on an AMT-105, a relay tester made by Vebko Amirkabir Company. Then the applicability of the proposed method was tested and analyzed completely using a distance relay of a real-life substation.