考虑局部水头损失的电-热一体化能源系统能量流计算

T. Ma, Qiuwei Wu, Qingqing Chi, Jian Chen
{"title":"考虑局部水头损失的电-热一体化能源系统能量流计算","authors":"T. Ma, Qiuwei Wu, Qingqing Chi, Jian Chen","doi":"10.1109/ICPEE51316.2020.9311033","DOIUrl":null,"url":null,"abstract":"Energy flow calculation of IES (integrated energy system) aims to calculate the node voltage and pressure, branch current and mass flow rate, working medium temperature and other state parameters according to known information. In the existing researches on energy flow calculation, only the friction head loss is considered and the influence of local head loss is not involved because of the complexity of the pipe structure. The local head loss occurring at abrupt flow boundary changes, such as variable section pipes, pipe inlet and outlet, and pipe connections is inevitable. The output of units and energy flow distribution in the IES will be affected by energy consumption caused by local head loss, so it is necessary to calculate the energy flow with local head loss in mind. In this paper, a local head loss energy model at pipe connection is first established, then a solution model for the energy flow of the electricity-heat IES with local head loss model is established, and the model can be solved by N-R method. Finally, the effectiveness of the model and the influence of local head loss on the whole system are verified through case comparison. The result shows that energy loss caused by local head loss should be avoided although it's a small amount of energy for the whole system.","PeriodicalId":321188,"journal":{"name":"2020 4th International Conference on Power and Energy Engineering (ICPEE)","volume":"113 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-11-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Energy Flow Calculation of Electricity-Heat Integrated Energy System Considering Local Head Loss\",\"authors\":\"T. Ma, Qiuwei Wu, Qingqing Chi, Jian Chen\",\"doi\":\"10.1109/ICPEE51316.2020.9311033\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Energy flow calculation of IES (integrated energy system) aims to calculate the node voltage and pressure, branch current and mass flow rate, working medium temperature and other state parameters according to known information. In the existing researches on energy flow calculation, only the friction head loss is considered and the influence of local head loss is not involved because of the complexity of the pipe structure. The local head loss occurring at abrupt flow boundary changes, such as variable section pipes, pipe inlet and outlet, and pipe connections is inevitable. The output of units and energy flow distribution in the IES will be affected by energy consumption caused by local head loss, so it is necessary to calculate the energy flow with local head loss in mind. In this paper, a local head loss energy model at pipe connection is first established, then a solution model for the energy flow of the electricity-heat IES with local head loss model is established, and the model can be solved by N-R method. Finally, the effectiveness of the model and the influence of local head loss on the whole system are verified through case comparison. The result shows that energy loss caused by local head loss should be avoided although it's a small amount of energy for the whole system.\",\"PeriodicalId\":321188,\"journal\":{\"name\":\"2020 4th International Conference on Power and Energy Engineering (ICPEE)\",\"volume\":\"113 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-11-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 4th International Conference on Power and Energy Engineering (ICPEE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPEE51316.2020.9311033\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 4th International Conference on Power and Energy Engineering (ICPEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPEE51316.2020.9311033","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

IES (integrated Energy system)能量流计算的目的是根据已知信息计算节点电压压力、支路电流和质量流量、工作介质温度等状态参数。在现有的能量流计算研究中,由于管道结构的复杂性,只考虑摩擦水头损失,没有考虑局部水头损失的影响。在变截面管道、管道进出口、管道连接等流动边界突变处发生局部水头损失是不可避免的。局部水头损失造成的能耗会影响电站机组的出力和能量流分布,因此有必要计算考虑局部水头损失的能量流。本文首先建立了管道连接处的局部水头损失能量模型,然后建立了具有局部水头损失模型的电热交换系统能量流的求解模型,该模型可采用N-R法求解。最后,通过实例对比验证了模型的有效性以及局部水头损失对整个系统的影响。结果表明,局部水头损失对整个系统的能量损失很小,但应尽量避免。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Energy Flow Calculation of Electricity-Heat Integrated Energy System Considering Local Head Loss
Energy flow calculation of IES (integrated energy system) aims to calculate the node voltage and pressure, branch current and mass flow rate, working medium temperature and other state parameters according to known information. In the existing researches on energy flow calculation, only the friction head loss is considered and the influence of local head loss is not involved because of the complexity of the pipe structure. The local head loss occurring at abrupt flow boundary changes, such as variable section pipes, pipe inlet and outlet, and pipe connections is inevitable. The output of units and energy flow distribution in the IES will be affected by energy consumption caused by local head loss, so it is necessary to calculate the energy flow with local head loss in mind. In this paper, a local head loss energy model at pipe connection is first established, then a solution model for the energy flow of the electricity-heat IES with local head loss model is established, and the model can be solved by N-R method. Finally, the effectiveness of the model and the influence of local head loss on the whole system are verified through case comparison. The result shows that energy loss caused by local head loss should be avoided although it's a small amount of energy for the whole system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信