{"title":"基于过程层网络的智能变电站保护系统可靠性评估","authors":"F. Xiao, Zhe Zhang, Xianggen Yin","doi":"10.1109/UPEC.2015.7339916","DOIUrl":null,"url":null,"abstract":"There are many forms of network structures in the process of smart substation layer. It is significant to research the process layer's reliability under different network structures of relay protection system for the network structure selection of process layer and engineering application. Based on the digitized substation relay protection system structure characteristic, this paper puts forward a reliability analysis method for protection system. The protection system is divided into sampling subsystem and trip subsystem and their fault tree models are established respectively. The method comprehensively considers the equipment failure and repair process and makes use of the fault tree and Monte Carlo simulation to solve the reliability of protection system. Finally, the proposed method is used to evaluate the reliability of the protection system with different network structures. The main elements affecting the reliability of protection system are given by the analysis of the component probability importance.","PeriodicalId":446482,"journal":{"name":"2015 50th International Universities Power Engineering Conference (UPEC)","volume":"236 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Reliability evaluation of protection system in smart substation based on process layer network\",\"authors\":\"F. Xiao, Zhe Zhang, Xianggen Yin\",\"doi\":\"10.1109/UPEC.2015.7339916\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"There are many forms of network structures in the process of smart substation layer. It is significant to research the process layer's reliability under different network structures of relay protection system for the network structure selection of process layer and engineering application. Based on the digitized substation relay protection system structure characteristic, this paper puts forward a reliability analysis method for protection system. The protection system is divided into sampling subsystem and trip subsystem and their fault tree models are established respectively. The method comprehensively considers the equipment failure and repair process and makes use of the fault tree and Monte Carlo simulation to solve the reliability of protection system. Finally, the proposed method is used to evaluate the reliability of the protection system with different network structures. The main elements affecting the reliability of protection system are given by the analysis of the component probability importance.\",\"PeriodicalId\":446482,\"journal\":{\"name\":\"2015 50th International Universities Power Engineering Conference (UPEC)\",\"volume\":\"236 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-12-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 50th International Universities Power Engineering Conference (UPEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/UPEC.2015.7339916\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 50th International Universities Power Engineering Conference (UPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/UPEC.2015.7339916","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Reliability evaluation of protection system in smart substation based on process layer network
There are many forms of network structures in the process of smart substation layer. It is significant to research the process layer's reliability under different network structures of relay protection system for the network structure selection of process layer and engineering application. Based on the digitized substation relay protection system structure characteristic, this paper puts forward a reliability analysis method for protection system. The protection system is divided into sampling subsystem and trip subsystem and their fault tree models are established respectively. The method comprehensively considers the equipment failure and repair process and makes use of the fault tree and Monte Carlo simulation to solve the reliability of protection system. Finally, the proposed method is used to evaluate the reliability of the protection system with different network structures. The main elements affecting the reliability of protection system are given by the analysis of the component probability importance.