9千赫至150千赫电器发射的实验室测量和栅格测量的比较

S. Lodetti, P. Davis, D. Ritzmann, P. Wright, V. Khokhlov, Jan Meyer, D. Istrate, K. Kasri, H. V. D. Brom, G. Ye, R. Leeuwen, A. Gallarreta, D. D. L. Vega
{"title":"9千赫至150千赫电器发射的实验室测量和栅格测量的比较","authors":"S. Lodetti, P. Davis, D. Ritzmann, P. Wright, V. Khokhlov, Jan Meyer, D. Istrate, K. Kasri, H. V. D. Brom, G. Ye, R. Leeuwen, A. Gallarreta, D. D. L. Vega","doi":"10.1109/AMPS55790.2022.9978783","DOIUrl":null,"url":null,"abstract":"The frequency range from 9 kHz to 150 kHz is still lacking a complete normative measurement framework. At the moment, it is not fully clear how well measurements of equipment emissions performed in laboratory environment compare with emissions measured in real low voltage networks, mainly due to different impedance conditions. This paper addresses this issue by presenting a comparison of emissions from a selected set of appliances measured in the laboratory with on-site low voltage network measurements of the same appliances. Several laboratories participated in this comparison, and different low voltage network locations have been taken into consideration. The comparison demonstrates overall agreement between the results obtained in different locations and conditions, especially where high-amplitude narrowband emissions are concerned. However, some differences have also been identified in the analysis between laboratory and grid measurements as well as between different laboratories. This might be due to the use of different (compliant) instruments with different characteristics or due to the use of artificial mains networks, which might not be fully representative of grid impedance.","PeriodicalId":253296,"journal":{"name":"2022 IEEE 12th International Workshop on Applied Measurements for Power Systems (AMPS)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Comparison of laboratory and grid measurements of 9 kHz to 150 kHz appliance emissions\",\"authors\":\"S. Lodetti, P. Davis, D. Ritzmann, P. Wright, V. Khokhlov, Jan Meyer, D. Istrate, K. Kasri, H. V. D. Brom, G. Ye, R. Leeuwen, A. Gallarreta, D. D. L. Vega\",\"doi\":\"10.1109/AMPS55790.2022.9978783\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The frequency range from 9 kHz to 150 kHz is still lacking a complete normative measurement framework. At the moment, it is not fully clear how well measurements of equipment emissions performed in laboratory environment compare with emissions measured in real low voltage networks, mainly due to different impedance conditions. This paper addresses this issue by presenting a comparison of emissions from a selected set of appliances measured in the laboratory with on-site low voltage network measurements of the same appliances. Several laboratories participated in this comparison, and different low voltage network locations have been taken into consideration. The comparison demonstrates overall agreement between the results obtained in different locations and conditions, especially where high-amplitude narrowband emissions are concerned. However, some differences have also been identified in the analysis between laboratory and grid measurements as well as between different laboratories. This might be due to the use of different (compliant) instruments with different characteristics or due to the use of artificial mains networks, which might not be fully representative of grid impedance.\",\"PeriodicalId\":253296,\"journal\":{\"name\":\"2022 IEEE 12th International Workshop on Applied Measurements for Power Systems (AMPS)\",\"volume\":\"13 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-09-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE 12th International Workshop on Applied Measurements for Power Systems (AMPS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/AMPS55790.2022.9978783\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE 12th International Workshop on Applied Measurements for Power Systems (AMPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AMPS55790.2022.9978783","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

从9khz到150khz的频率范围仍然缺乏一个完整的规范的测量框架。目前,还不完全清楚在实验室环境中进行的设备排放测量与在实际低压网络中测量的排放相比如何,主要是由于阻抗条件不同。本文通过对实验室测量的一组选定电器的排放与现场低压网络测量的相同电器的排放进行比较,解决了这个问题。几个实验室参与了这个比较,并考虑了不同的低压网络位置。比较表明,在不同位置和条件下获得的结果总体上是一致的,特别是在高振幅窄带发射的情况下。然而,在实验室测量和网格测量之间以及不同实验室之间的分析中也发现了一些差异。这可能是由于使用了具有不同特性的不同(兼容)仪器,或者由于使用了人工市电网络,这可能不能完全代表电网阻抗。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of laboratory and grid measurements of 9 kHz to 150 kHz appliance emissions
The frequency range from 9 kHz to 150 kHz is still lacking a complete normative measurement framework. At the moment, it is not fully clear how well measurements of equipment emissions performed in laboratory environment compare with emissions measured in real low voltage networks, mainly due to different impedance conditions. This paper addresses this issue by presenting a comparison of emissions from a selected set of appliances measured in the laboratory with on-site low voltage network measurements of the same appliances. Several laboratories participated in this comparison, and different low voltage network locations have been taken into consideration. The comparison demonstrates overall agreement between the results obtained in different locations and conditions, especially where high-amplitude narrowband emissions are concerned. However, some differences have also been identified in the analysis between laboratory and grid measurements as well as between different laboratories. This might be due to the use of different (compliant) instruments with different characteristics or due to the use of artificial mains networks, which might not be fully representative of grid impedance.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信