用于植入医疗设备的螺旋线圈的Sub-GHz感应功率传输

A. Diet, S. Koulouridis, Y. Le Bihan, Q.-T. Luu, O. Meyer, L. Pichon, M. Biancheri-Astier
{"title":"用于植入医疗设备的螺旋线圈的Sub-GHz感应功率传输","authors":"A. Diet, S. Koulouridis, Y. Le Bihan, Q.-T. Luu, O. Meyer, L. Pichon, M. Biancheri-Astier","doi":"10.1109/IWAT.2017.7915348","DOIUrl":null,"url":null,"abstract":"This paper presents some measurements and simulations results in which small helicoidally coils are designed, in the idea to provide a RF power transfer for implanted medical devices (IMDs). In such context, the coils should be very small if they are implanted within devices, or even if they are used as an alternate solution combined with UHF antennas (ex. PIFA). The influence of the body and the mandatory small size of the coils bring a difficult technological lock concerning efficiency and measurements accuracy which must validate our simulations. In this paper, a deembedding technique is used to take into account the dedicated test fixture, and further works will investigate the electromagnetic influence of a liquid phantom, modeling the muscle tissue.","PeriodicalId":289886,"journal":{"name":"2017 International Workshop on Antenna Technology: Small Antennas, Innovative Structures, and Applications (iWAT)","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Sub-GHz inductive power transmission from helical coils for implanted medical devices\",\"authors\":\"A. Diet, S. Koulouridis, Y. Le Bihan, Q.-T. Luu, O. Meyer, L. Pichon, M. Biancheri-Astier\",\"doi\":\"10.1109/IWAT.2017.7915348\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents some measurements and simulations results in which small helicoidally coils are designed, in the idea to provide a RF power transfer for implanted medical devices (IMDs). In such context, the coils should be very small if they are implanted within devices, or even if they are used as an alternate solution combined with UHF antennas (ex. PIFA). The influence of the body and the mandatory small size of the coils bring a difficult technological lock concerning efficiency and measurements accuracy which must validate our simulations. In this paper, a deembedding technique is used to take into account the dedicated test fixture, and further works will investigate the electromagnetic influence of a liquid phantom, modeling the muscle tissue.\",\"PeriodicalId\":289886,\"journal\":{\"name\":\"2017 International Workshop on Antenna Technology: Small Antennas, Innovative Structures, and Applications (iWAT)\",\"volume\":\"31 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 International Workshop on Antenna Technology: Small Antennas, Innovative Structures, and Applications (iWAT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IWAT.2017.7915348\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 International Workshop on Antenna Technology: Small Antennas, Innovative Structures, and Applications (iWAT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IWAT.2017.7915348","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了一些测量和仿真结果,其中设计了小螺旋线圈,为植入式医疗设备(imd)提供射频功率传输。在这种情况下,如果线圈被植入设备内,或者即使它们被用作与超高频天线(例如PIFA)结合的替代解决方案,线圈应该非常小。由于人体的影响和线圈的强制小尺寸,在效率和测量精度方面带来了技术上的困难,这必须验证我们的仿真。在本文中,考虑到专用的测试夹具,使用了一种去嵌入技术,进一步的工作将研究液体模体的电磁影响,模拟肌肉组织。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Sub-GHz inductive power transmission from helical coils for implanted medical devices
This paper presents some measurements and simulations results in which small helicoidally coils are designed, in the idea to provide a RF power transfer for implanted medical devices (IMDs). In such context, the coils should be very small if they are implanted within devices, or even if they are used as an alternate solution combined with UHF antennas (ex. PIFA). The influence of the body and the mandatory small size of the coils bring a difficult technological lock concerning efficiency and measurements accuracy which must validate our simulations. In this paper, a deembedding technique is used to take into account the dedicated test fixture, and further works will investigate the electromagnetic influence of a liquid phantom, modeling the muscle tissue.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信