{"title":"保卫电网:安装不可扩展的控制系统","authors":"Robert Koch, T. Kuhn","doi":"10.23919/CYCON.2017.8240335","DOIUrl":null,"url":null,"abstract":"Network security has been a lively research area for more than 35 years and numerous products are available nowadays. In contrast to business networks, which were interconnected from the beginning by design, Industrial Control Systems (ICSs) have always been self-contained networks. Because their key features are real-time capability and their operational constraint to function as specified under maximum load (Carlson 1998), security has played only a subordinate role. Nowadays these systems are increasingly connected to the Internet; for example, wind power is more frequently used and generators are installed in remote and scattered regions that are difficult to access, so remote administration based on mobile communications is required, often using the Internet. While numerous papers on securing ICSs have been published, interest rose after the incidents in Iran's enrichment plant in Natanz where the SCADA system controlling the centrifuges was attacked by the Stuxnet worm. Even with these intensified efforts, the current security situation is insufficient as numerous security systems perform inadequately in real-world environments. Elderly ICSs are also still in use which cannot be retrofitted easily or at all, and modern systems are often still not developed with ‘security by design’ in mind. In contrast to general purpose systems, a relatively limited number of processes are executed within ICSs. This enables the use of detection mechanisms based on voltage levels and current drain to build lightweight detection systems without huge databases by measuring the current drain during normal system operation. Our concept combines the advantages of different detection principles and enhances them to build an Intrusion Detection System usable within ICSs. It is implemented based on low-priced components and can be integrated even in older, originally non-expandable systems.","PeriodicalId":423770,"journal":{"name":"2017 9th International Conference on Cyber Conflict (CyCon)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Defending the grid: Backfitting non-expandable control systems\",\"authors\":\"Robert Koch, T. Kuhn\",\"doi\":\"10.23919/CYCON.2017.8240335\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Network security has been a lively research area for more than 35 years and numerous products are available nowadays. In contrast to business networks, which were interconnected from the beginning by design, Industrial Control Systems (ICSs) have always been self-contained networks. Because their key features are real-time capability and their operational constraint to function as specified under maximum load (Carlson 1998), security has played only a subordinate role. Nowadays these systems are increasingly connected to the Internet; for example, wind power is more frequently used and generators are installed in remote and scattered regions that are difficult to access, so remote administration based on mobile communications is required, often using the Internet. While numerous papers on securing ICSs have been published, interest rose after the incidents in Iran's enrichment plant in Natanz where the SCADA system controlling the centrifuges was attacked by the Stuxnet worm. Even with these intensified efforts, the current security situation is insufficient as numerous security systems perform inadequately in real-world environments. Elderly ICSs are also still in use which cannot be retrofitted easily or at all, and modern systems are often still not developed with ‘security by design’ in mind. In contrast to general purpose systems, a relatively limited number of processes are executed within ICSs. This enables the use of detection mechanisms based on voltage levels and current drain to build lightweight detection systems without huge databases by measuring the current drain during normal system operation. Our concept combines the advantages of different detection principles and enhances them to build an Intrusion Detection System usable within ICSs. It is implemented based on low-priced components and can be integrated even in older, originally non-expandable systems.\",\"PeriodicalId\":423770,\"journal\":{\"name\":\"2017 9th International Conference on Cyber Conflict (CyCon)\",\"volume\":\"9 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 9th International Conference on Cyber Conflict (CyCon)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23919/CYCON.2017.8240335\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 9th International Conference on Cyber Conflict (CyCon)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/CYCON.2017.8240335","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

网络安全已经成为一个活跃的研究领域超过35年,现在有许多产品可供选择。与从设计开始就相互连接的商业网络不同,工业控制系统(ics)一直是独立的网络。因为它们的主要特征是实时性和在最大负载下的操作约束(Carlson 1998),所以安全性只扮演了次要的角色。如今,这些系统越来越多地连接到互联网;例如,风力发电的使用频率更高,发电机安装在偏远和分散的地区,难以进入,因此需要基于移动通信的远程管理,通常使用互联网。虽然已经发表了许多关于确保国际空间站安全的论文,但在伊朗纳坦兹铀浓缩工厂发生事件后,控制离心机的SCADA系统遭到了震网蠕虫病毒的攻击,人们的兴趣上升了。即使有了这些加强的努力,目前的安全状况是不够的,因为许多安全系统在现实环境中表现不佳。老旧的集成电路系统也仍在使用,无法轻易或根本无法改装,而现代系统在开发时往往仍未考虑到“设计安全”。与通用系统相比,在集成系统中执行的进程数量相对有限。这使得使用基于电压水平和漏电流的检测机制能够通过测量正常系统运行期间的漏电流来构建轻量级检测系统,而无需庞大的数据库。我们的概念结合了不同检测原理的优点,并对其进行了增强,以构建一个可用于ics的入侵检测系统。它是基于低价组件实现的,甚至可以集成到较旧的、最初不可扩展的系统中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Defending the grid: Backfitting non-expandable control systems
Network security has been a lively research area for more than 35 years and numerous products are available nowadays. In contrast to business networks, which were interconnected from the beginning by design, Industrial Control Systems (ICSs) have always been self-contained networks. Because their key features are real-time capability and their operational constraint to function as specified under maximum load (Carlson 1998), security has played only a subordinate role. Nowadays these systems are increasingly connected to the Internet; for example, wind power is more frequently used and generators are installed in remote and scattered regions that are difficult to access, so remote administration based on mobile communications is required, often using the Internet. While numerous papers on securing ICSs have been published, interest rose after the incidents in Iran's enrichment plant in Natanz where the SCADA system controlling the centrifuges was attacked by the Stuxnet worm. Even with these intensified efforts, the current security situation is insufficient as numerous security systems perform inadequately in real-world environments. Elderly ICSs are also still in use which cannot be retrofitted easily or at all, and modern systems are often still not developed with ‘security by design’ in mind. In contrast to general purpose systems, a relatively limited number of processes are executed within ICSs. This enables the use of detection mechanisms based on voltage levels and current drain to build lightweight detection systems without huge databases by measuring the current drain during normal system operation. Our concept combines the advantages of different detection principles and enhances them to build an Intrusion Detection System usable within ICSs. It is implemented based on low-priced components and can be integrated even in older, originally non-expandable systems.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信