{"title":"盐雾条件下涂覆绝缘子泄漏电流的实验研究","authors":"Hugo Linhares Dias Espinola, I. Lopes","doi":"10.21439/jme.v2i3.27","DOIUrl":null,"url":null,"abstract":"The accumulation of contaminants in electrical insulators reduce their performance and may lead to failures. Estimating the degree of pollution of in-service equipment is not a trivial task as the process of contamination depends on several factors. It is necessary to monitor the insulators so that preventive measures can be taken in a timely manner. In this context, this paper aims to study how the amplitude, angular phase and total harmonic distortion (THD) of the leakage current can be used to monitor insulators and how these parameters are affected by the application of hydrophobic coatings. For this purpose, standard uncoated and coated glass insulator samples were subjected to electrical tests in a salt-fog chamber while the leakage current was monitored. The results show that the analyzed parameters provide relevant information about the insulation condition and how the application of hydrophobic coatings results in improvements in the insulator performance.","PeriodicalId":303991,"journal":{"name":"Journal of Mechatronics Engineering","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Experimental Study of the Leakage Current in Coated Insulators Under Salt-Fog Conditions\",\"authors\":\"Hugo Linhares Dias Espinola, I. Lopes\",\"doi\":\"10.21439/jme.v2i3.27\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The accumulation of contaminants in electrical insulators reduce their performance and may lead to failures. Estimating the degree of pollution of in-service equipment is not a trivial task as the process of contamination depends on several factors. It is necessary to monitor the insulators so that preventive measures can be taken in a timely manner. In this context, this paper aims to study how the amplitude, angular phase and total harmonic distortion (THD) of the leakage current can be used to monitor insulators and how these parameters are affected by the application of hydrophobic coatings. For this purpose, standard uncoated and coated glass insulator samples were subjected to electrical tests in a salt-fog chamber while the leakage current was monitored. The results show that the analyzed parameters provide relevant information about the insulation condition and how the application of hydrophobic coatings results in improvements in the insulator performance.\",\"PeriodicalId\":303991,\"journal\":{\"name\":\"Journal of Mechatronics Engineering\",\"volume\":\"41 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-09-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Mechatronics Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21439/jme.v2i3.27\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Mechatronics Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21439/jme.v2i3.27","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

电绝缘体中污染物的积累会降低其性能并可能导致故障。估计在役设备的污染程度并不是一项简单的任务,因为污染的过程取决于几个因素。有必要对绝缘子进行监测,以便及时采取预防措施。在此背景下,本文旨在研究如何利用泄漏电流的幅值、角相和总谐波失真(THD)来监测绝缘子,以及疏水涂层的应用对这些参数的影响。为此,标准的未涂覆和涂覆玻璃绝缘体样品在盐雾室中进行电气测试,同时监测泄漏电流。结果表明,所分析的参数提供了绝缘子绝缘状况的相关信息,以及疏水涂层的应用如何改善绝缘子的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Experimental Study of the Leakage Current in Coated Insulators Under Salt-Fog Conditions
The accumulation of contaminants in electrical insulators reduce their performance and may lead to failures. Estimating the degree of pollution of in-service equipment is not a trivial task as the process of contamination depends on several factors. It is necessary to monitor the insulators so that preventive measures can be taken in a timely manner. In this context, this paper aims to study how the amplitude, angular phase and total harmonic distortion (THD) of the leakage current can be used to monitor insulators and how these parameters are affected by the application of hydrophobic coatings. For this purpose, standard uncoated and coated glass insulator samples were subjected to electrical tests in a salt-fog chamber while the leakage current was monitored. The results show that the analyzed parameters provide relevant information about the insulation condition and how the application of hydrophobic coatings results in improvements in the insulator performance.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信