Xiaomeng Gao, Xiaonan Jiang, Songjie Bi, D. Matthews, S. Schaefer, X. Liu
{"title":"使用接触式多普勒雷达测量复杂的人房室运动","authors":"Xiaomeng Gao, Xiaonan Jiang, Songjie Bi, D. Matthews, S. Schaefer, X. Liu","doi":"10.1109/WAMICON.2019.8765441","DOIUrl":null,"url":null,"abstract":"Contact-based cardiac motion detection using Quadrature Doppler radar faces a challenge of the I/Q-formed non-arc constellation. In this work, a hypothesis is brought forward that such complicated constellation originates from not one, but two moving targets. The dual-motion model may very well explain that contact-based Doppler radar detects both atrium and ventricle motions during cardiac cycles. In this work, dual-motion simulation and phantom measurements are presented, verifying that the atrial-ventricular motions are the reason that I/Q baseband signals transcribe a complex non-arc constellation. It offers the first evidence that contact-based Doppler radar measures actual heart motion.","PeriodicalId":328717,"journal":{"name":"2019 IEEE 20th Wireless and Microwave Technology Conference (WAMICON)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Measurement of the Complex Human Atrial-Ventricular Motions using Contact-Based Doppler Radar\",\"authors\":\"Xiaomeng Gao, Xiaonan Jiang, Songjie Bi, D. Matthews, S. Schaefer, X. Liu\",\"doi\":\"10.1109/WAMICON.2019.8765441\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Contact-based cardiac motion detection using Quadrature Doppler radar faces a challenge of the I/Q-formed non-arc constellation. In this work, a hypothesis is brought forward that such complicated constellation originates from not one, but two moving targets. The dual-motion model may very well explain that contact-based Doppler radar detects both atrium and ventricle motions during cardiac cycles. In this work, dual-motion simulation and phantom measurements are presented, verifying that the atrial-ventricular motions are the reason that I/Q baseband signals transcribe a complex non-arc constellation. It offers the first evidence that contact-based Doppler radar measures actual heart motion.\",\"PeriodicalId\":328717,\"journal\":{\"name\":\"2019 IEEE 20th Wireless and Microwave Technology Conference (WAMICON)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE 20th Wireless and Microwave Technology Conference (WAMICON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/WAMICON.2019.8765441\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE 20th Wireless and Microwave Technology Conference (WAMICON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/WAMICON.2019.8765441","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Measurement of the Complex Human Atrial-Ventricular Motions using Contact-Based Doppler Radar
Contact-based cardiac motion detection using Quadrature Doppler radar faces a challenge of the I/Q-formed non-arc constellation. In this work, a hypothesis is brought forward that such complicated constellation originates from not one, but two moving targets. The dual-motion model may very well explain that contact-based Doppler radar detects both atrium and ventricle motions during cardiac cycles. In this work, dual-motion simulation and phantom measurements are presented, verifying that the atrial-ventricular motions are the reason that I/Q baseband signals transcribe a complex non-arc constellation. It offers the first evidence that contact-based Doppler radar measures actual heart motion.