Mohammad Mehrabikooshki, S. Mirhosseini, S. Jamali
{"title":"基于输电线路电流高频分量的LCC- HVDC输电线路单端保护方案","authors":"Mohammad Mehrabikooshki, S. Mirhosseini, S. Jamali","doi":"10.1109/IPAPS49326.2019.9069381","DOIUrl":null,"url":null,"abstract":"This paper proposes a single-end protection scheme based on high frequency components of DC line current for protection of transmission lines in LCC-HVDC system. The protection scheme deploys the boundary characteristics of transmission line which eliminates high frequency components of external faults due to presence of filter-reactor unit at the line terminal. The scheme consists of two criteria including fault detection criterion and protection criterion to distinguish between internal and external faults. The performance of the protection scheme is evaluated by performing numerous simulation studies considering different fault locations, fault resistance, length of data window, sampling frequency and change in the transmission line power as well. The simulation results confirm that the proposed protection scheme is capable of discriminating between different types of high resistance internal faults and external faults at DC and AC sides using only rectifier side measurements. Moreover, it is simple, fast and reliable, and does not need communication between transmission line ends.","PeriodicalId":230294,"journal":{"name":"2020 14th International Conference on Protection and Automation of Power Systems (IPAPS)","volume":"131 8","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Single-End Protection Scheme for LCC- HVDC Transmission Lines Based on High Frequency Components of Transmission Line Current\",\"authors\":\"Mohammad Mehrabikooshki, S. Mirhosseini, S. Jamali\",\"doi\":\"10.1109/IPAPS49326.2019.9069381\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a single-end protection scheme based on high frequency components of DC line current for protection of transmission lines in LCC-HVDC system. The protection scheme deploys the boundary characteristics of transmission line which eliminates high frequency components of external faults due to presence of filter-reactor unit at the line terminal. The scheme consists of two criteria including fault detection criterion and protection criterion to distinguish between internal and external faults. The performance of the protection scheme is evaluated by performing numerous simulation studies considering different fault locations, fault resistance, length of data window, sampling frequency and change in the transmission line power as well. The simulation results confirm that the proposed protection scheme is capable of discriminating between different types of high resistance internal faults and external faults at DC and AC sides using only rectifier side measurements. Moreover, it is simple, fast and reliable, and does not need communication between transmission line ends.\",\"PeriodicalId\":230294,\"journal\":{\"name\":\"2020 14th International Conference on Protection and Automation of Power Systems (IPAPS)\",\"volume\":\"131 8\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 14th International Conference on Protection and Automation of Power Systems (IPAPS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IPAPS49326.2019.9069381\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 14th International Conference on Protection and Automation of Power Systems (IPAPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPAPS49326.2019.9069381","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Single-End Protection Scheme for LCC- HVDC Transmission Lines Based on High Frequency Components of Transmission Line Current
This paper proposes a single-end protection scheme based on high frequency components of DC line current for protection of transmission lines in LCC-HVDC system. The protection scheme deploys the boundary characteristics of transmission line which eliminates high frequency components of external faults due to presence of filter-reactor unit at the line terminal. The scheme consists of two criteria including fault detection criterion and protection criterion to distinguish between internal and external faults. The performance of the protection scheme is evaluated by performing numerous simulation studies considering different fault locations, fault resistance, length of data window, sampling frequency and change in the transmission line power as well. The simulation results confirm that the proposed protection scheme is capable of discriminating between different types of high resistance internal faults and external faults at DC and AC sides using only rectifier side measurements. Moreover, it is simple, fast and reliable, and does not need communication between transmission line ends.