基于直接转换多普勒雷达的人体运动盲源分离

A. Vergara, N. Petrochilos, O. Boric-Lubecke, A. Høst-Madsen, V. Lubecke
{"title":"基于直接转换多普勒雷达的人体运动盲源分离","authors":"A. Vergara, N. Petrochilos, O. Boric-Lubecke, A. Høst-Madsen, V. Lubecke","doi":"10.1109/MWSYM.2008.4633306","DOIUrl":null,"url":null,"abstract":"Direct conversion Doppler radar can provide remote non-invasive monitoring of cardio-pulmonary activity of human subjects. However, real world life signs monitoring requires real-time processing of data over long monitoring periods, during which it is unlikely that the subject can be expected to suppress other body motion. Measurement of cardiopulmonary motion of a human subject with extraneous subject movement in the field of view of a Doppler radar system is a complex problem. The use of multiple antennas and blind source separation signal processing techniques is a logical approach for monitoring humans in real world conditions. Described here is the successful separation of cardiopulmonary motion and hand motion for a single subject.","PeriodicalId":273767,"journal":{"name":"2008 IEEE MTT-S International Microwave Symposium Digest","volume":"76 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-06-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"27","resultStr":"{\"title\":\"Blind source separation of human body motion using direct conversion Doppler radar\",\"authors\":\"A. Vergara, N. Petrochilos, O. Boric-Lubecke, A. Høst-Madsen, V. Lubecke\",\"doi\":\"10.1109/MWSYM.2008.4633306\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Direct conversion Doppler radar can provide remote non-invasive monitoring of cardio-pulmonary activity of human subjects. However, real world life signs monitoring requires real-time processing of data over long monitoring periods, during which it is unlikely that the subject can be expected to suppress other body motion. Measurement of cardiopulmonary motion of a human subject with extraneous subject movement in the field of view of a Doppler radar system is a complex problem. The use of multiple antennas and blind source separation signal processing techniques is a logical approach for monitoring humans in real world conditions. Described here is the successful separation of cardiopulmonary motion and hand motion for a single subject.\",\"PeriodicalId\":273767,\"journal\":{\"name\":\"2008 IEEE MTT-S International Microwave Symposium Digest\",\"volume\":\"76 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-06-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"27\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 IEEE MTT-S International Microwave Symposium Digest\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MWSYM.2008.4633306\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 IEEE MTT-S International Microwave Symposium Digest","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MWSYM.2008.4633306","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 27

摘要

直接转换多普勒雷达可提供人体心肺活动的远程无创监测。然而,现实世界的生命体征监测需要在长时间的监测期间实时处理数据,在此期间,受试者不太可能被期望抑制其他身体运动。在多普勒雷达系统的视场中测量人体体外运动是一个复杂的问题。使用多天线和盲源分离信号处理技术是在现实世界条件下监测人类的一种合乎逻辑的方法。这里描述的是成功分离心肺运动和手部运动为一个单一的主题。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Blind source separation of human body motion using direct conversion Doppler radar
Direct conversion Doppler radar can provide remote non-invasive monitoring of cardio-pulmonary activity of human subjects. However, real world life signs monitoring requires real-time processing of data over long monitoring periods, during which it is unlikely that the subject can be expected to suppress other body motion. Measurement of cardiopulmonary motion of a human subject with extraneous subject movement in the field of view of a Doppler radar system is a complex problem. The use of multiple antennas and blind source separation signal processing techniques is a logical approach for monitoring humans in real world conditions. Described here is the successful separation of cardiopulmonary motion and hand motion for a single subject.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信