骨科手术中导航用术中透视无ct容积重建系统的设计与评估

Marcus Tatum, G. Thomas, D. Anderson
{"title":"骨科手术中导航用术中透视无ct容积重建系统的设计与评估","authors":"Marcus Tatum, G. Thomas, D. Anderson","doi":"10.1115/dmd2023-9640","DOIUrl":null,"url":null,"abstract":"\n A novel biomechanical guidance system (BGS) for markerless intra-operative bone tracking that seamlessly integrates into the surgical setting was recently developed [1]. It utilizes 3D models from pre-operative CT, via 3D-to-2D registration methods, to update object poses based on 2D fluoroscopic images. However, on occasion pre-operative CT images may be unavailable. We developed a CT-free method to enable BGS use that leverages neural radiance fields (NeRF) to generate a continuous volumetric scene [2,3] from intra-operative fluoroscopy. For proof of concept, digitally reconstructed radiographs (DRRs) were created from pelvic CT data as a stand-in for intra-operative fluoroscopy. DRRs and virtual C-arm positions were fed into an existing NeRF scene reconstruction system,[2,3] and bones were segmented from the reconstruction. The accuracy of NeRF-derived segmentations was evaluated by comparison to gold-standard CT segmentation. The number of input DRRs was varied to study how this parameter influences reconstructions. Volume reconstructions were readily obtained using the NeRF scene reconstruction system. RMS errors of the NeRF-derived segmentations ranged from 1.23 mm when using 36 input DRR images to 1.98 mm when using only 8 input DRR images. Based on this performance, we conclude that CT-free NeRF volume reconstruction from intra-operative fluoroscopy holds great potential for use in surgical navigation applications involving bony procedures.","PeriodicalId":325836,"journal":{"name":"2023 Design of Medical Devices Conference","volume":"52 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"DESIGN AND EVALUATION OF A SYSTEM FOR CT-FREE VOLUME RECONSTRUCTION FROM INTRA-OPERATIVE FLUOROSCOPY FOR NAVIGATION IN ORTHOPEDIC SURGERY\",\"authors\":\"Marcus Tatum, G. Thomas, D. Anderson\",\"doi\":\"10.1115/dmd2023-9640\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n A novel biomechanical guidance system (BGS) for markerless intra-operative bone tracking that seamlessly integrates into the surgical setting was recently developed [1]. It utilizes 3D models from pre-operative CT, via 3D-to-2D registration methods, to update object poses based on 2D fluoroscopic images. However, on occasion pre-operative CT images may be unavailable. We developed a CT-free method to enable BGS use that leverages neural radiance fields (NeRF) to generate a continuous volumetric scene [2,3] from intra-operative fluoroscopy. For proof of concept, digitally reconstructed radiographs (DRRs) were created from pelvic CT data as a stand-in for intra-operative fluoroscopy. DRRs and virtual C-arm positions were fed into an existing NeRF scene reconstruction system,[2,3] and bones were segmented from the reconstruction. The accuracy of NeRF-derived segmentations was evaluated by comparison to gold-standard CT segmentation. The number of input DRRs was varied to study how this parameter influences reconstructions. Volume reconstructions were readily obtained using the NeRF scene reconstruction system. RMS errors of the NeRF-derived segmentations ranged from 1.23 mm when using 36 input DRR images to 1.98 mm when using only 8 input DRR images. Based on this performance, we conclude that CT-free NeRF volume reconstruction from intra-operative fluoroscopy holds great potential for use in surgical navigation applications involving bony procedures.\",\"PeriodicalId\":325836,\"journal\":{\"name\":\"2023 Design of Medical Devices Conference\",\"volume\":\"52 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-04-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 Design of Medical Devices Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/dmd2023-9640\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 Design of Medical Devices Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/dmd2023-9640","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

最近开发了一种新的生物力学引导系统(BGS),用于术中无标记骨跟踪,无缝集成到手术环境中[1]。它利用术前CT的3D模型,通过3D到2D的配准方法,根据2D透视图像更新物体姿态。然而,有时术前CT图像可能不可用。我们开发了一种无需ct的BGS使用方法,利用神经辐射场(NeRF)从术中透视产生连续的体积场景[2,3]。为了证明这一概念,从骨盆CT数据创建了数字重建x线片(DRRs),作为术中透视检查的替代品。将DRRs和虚拟c臂位置输入到现有的NeRF场景重建系统中,[2,3]并从重建中分割骨骼。通过与金标准CT分割的比较,评估了nerf衍生分割的准确性。通过改变输入drr的数量来研究该参数对重建的影响。使用NeRF场景重建系统可以很容易地获得体重建。在使用36张输入DRR图像时,nerf衍生分割的均方根误差为1.23 mm,而仅使用8张输入DRR图像时,其均方根误差为1.98 mm。基于这一表现,我们得出结论,术中透视无ct NeRF体积重建在涉及骨手术的外科导航应用中具有巨大的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
DESIGN AND EVALUATION OF A SYSTEM FOR CT-FREE VOLUME RECONSTRUCTION FROM INTRA-OPERATIVE FLUOROSCOPY FOR NAVIGATION IN ORTHOPEDIC SURGERY
A novel biomechanical guidance system (BGS) for markerless intra-operative bone tracking that seamlessly integrates into the surgical setting was recently developed [1]. It utilizes 3D models from pre-operative CT, via 3D-to-2D registration methods, to update object poses based on 2D fluoroscopic images. However, on occasion pre-operative CT images may be unavailable. We developed a CT-free method to enable BGS use that leverages neural radiance fields (NeRF) to generate a continuous volumetric scene [2,3] from intra-operative fluoroscopy. For proof of concept, digitally reconstructed radiographs (DRRs) were created from pelvic CT data as a stand-in for intra-operative fluoroscopy. DRRs and virtual C-arm positions were fed into an existing NeRF scene reconstruction system,[2,3] and bones were segmented from the reconstruction. The accuracy of NeRF-derived segmentations was evaluated by comparison to gold-standard CT segmentation. The number of input DRRs was varied to study how this parameter influences reconstructions. Volume reconstructions were readily obtained using the NeRF scene reconstruction system. RMS errors of the NeRF-derived segmentations ranged from 1.23 mm when using 36 input DRR images to 1.98 mm when using only 8 input DRR images. Based on this performance, we conclude that CT-free NeRF volume reconstruction from intra-operative fluoroscopy holds great potential for use in surgical navigation applications involving bony procedures.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信