{"title":"卡尔曼滤波在心律失常检测中的应用","authors":"L. Szilágyi","doi":"10.1109/IEMBS.1998.745834","DOIUrl":null,"url":null,"abstract":"The variability of the R-R intervals in the ECG signal contains valuable information about the various types of arrhythmia that might be present. It has been recently suggested, that the identification of cardiac arrhythmia might be possible by applying spectral analysis methods. This paper intends to investigate the efficiency of a spectral analysis method, namely the application of the Kalman filter identifier in the calculation of time varying spectra of the R-R interval time series. The efficiency of the method is tested using the MIT-BIH database and another database built up at the Medical Clinic No. 3 of Tg. Mures; in particular, cases of bigeminy, trigeminy, second degree block and ventricular flutter have been tested. Tests have revealed, that this technique in most cases can detect the onset of arrhythmia and can also identify the arrhythmia that is present.","PeriodicalId":156581,"journal":{"name":"Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Vol.20 Biomedical Engineering Towards the Year 2000 and Beyond (Cat. No.98CH36286)","volume":"47 2","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"Application of the Kalman filter in cardiac arrhythmia detection\",\"authors\":\"L. Szilágyi\",\"doi\":\"10.1109/IEMBS.1998.745834\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The variability of the R-R intervals in the ECG signal contains valuable information about the various types of arrhythmia that might be present. It has been recently suggested, that the identification of cardiac arrhythmia might be possible by applying spectral analysis methods. This paper intends to investigate the efficiency of a spectral analysis method, namely the application of the Kalman filter identifier in the calculation of time varying spectra of the R-R interval time series. The efficiency of the method is tested using the MIT-BIH database and another database built up at the Medical Clinic No. 3 of Tg. Mures; in particular, cases of bigeminy, trigeminy, second degree block and ventricular flutter have been tested. Tests have revealed, that this technique in most cases can detect the onset of arrhythmia and can also identify the arrhythmia that is present.\",\"PeriodicalId\":156581,\"journal\":{\"name\":\"Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Vol.20 Biomedical Engineering Towards the Year 2000 and Beyond (Cat. No.98CH36286)\",\"volume\":\"47 2\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-10-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Vol.20 Biomedical Engineering Towards the Year 2000 and Beyond (Cat. No.98CH36286)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IEMBS.1998.745834\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Vol.20 Biomedical Engineering Towards the Year 2000 and Beyond (Cat. No.98CH36286)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMBS.1998.745834","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Application of the Kalman filter in cardiac arrhythmia detection
The variability of the R-R intervals in the ECG signal contains valuable information about the various types of arrhythmia that might be present. It has been recently suggested, that the identification of cardiac arrhythmia might be possible by applying spectral analysis methods. This paper intends to investigate the efficiency of a spectral analysis method, namely the application of the Kalman filter identifier in the calculation of time varying spectra of the R-R interval time series. The efficiency of the method is tested using the MIT-BIH database and another database built up at the Medical Clinic No. 3 of Tg. Mures; in particular, cases of bigeminy, trigeminy, second degree block and ventricular flutter have been tested. Tests have revealed, that this technique in most cases can detect the onset of arrhythmia and can also identify the arrhythmia that is present.