Soungchul Park, Wooyoung Kim, Suhwan Kim, Jooyeol Rhee
{"title":"一种133.3 dB动态范围脉搏血氧仪前端,具有低噪声区域高效失调抵消电流DAC","authors":"Soungchul Park, Wooyoung Kim, Suhwan Kim, Jooyeol Rhee","doi":"10.1109/ICEIC57457.2023.10049972","DOIUrl":null,"url":null,"abstract":"This paper introduces a pulse oximeter front-end with low-noise area-efficient offset cancellation current digital-to-analog converter (DAC). The proposed offset cancellation current DAC is implemented to cancel the input DC current to improve the effective dynamic range (DR). The current DAC is designed to have low-noise and area-efficient characteristics by applying the dynamic element matching technique and reducing the number of idle current mirror transistors. It can generate a current of up to 256 μA. Due to the offset cancellation of the current DAC, the proposed pulse oximeter has a signal-to-noise ratio of 77.4 dB and an effective DR of 133.3 dB. The pulse oximeter front-end is designed in 0.13 μm CMOS and consumes 307.1 μW from a 1.65 V supply. The figure-of-merit is 0.81 pJ/Sample.","PeriodicalId":373752,"journal":{"name":"2023 International Conference on Electronics, Information, and Communication (ICEIC)","volume":"1473 ","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-02-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A 133.3 dB Dynamic Range Pulse Oximeter Front-End with Low-Noise Area-Efficient Offset Cancellation Current DAC\",\"authors\":\"Soungchul Park, Wooyoung Kim, Suhwan Kim, Jooyeol Rhee\",\"doi\":\"10.1109/ICEIC57457.2023.10049972\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper introduces a pulse oximeter front-end with low-noise area-efficient offset cancellation current digital-to-analog converter (DAC). The proposed offset cancellation current DAC is implemented to cancel the input DC current to improve the effective dynamic range (DR). The current DAC is designed to have low-noise and area-efficient characteristics by applying the dynamic element matching technique and reducing the number of idle current mirror transistors. It can generate a current of up to 256 μA. Due to the offset cancellation of the current DAC, the proposed pulse oximeter has a signal-to-noise ratio of 77.4 dB and an effective DR of 133.3 dB. The pulse oximeter front-end is designed in 0.13 μm CMOS and consumes 307.1 μW from a 1.65 V supply. The figure-of-merit is 0.81 pJ/Sample.\",\"PeriodicalId\":373752,\"journal\":{\"name\":\"2023 International Conference on Electronics, Information, and Communication (ICEIC)\",\"volume\":\"1473 \",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-02-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 International Conference on Electronics, Information, and Communication (ICEIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEIC57457.2023.10049972\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 International Conference on Electronics, Information, and Communication (ICEIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEIC57457.2023.10049972","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A 133.3 dB Dynamic Range Pulse Oximeter Front-End with Low-Noise Area-Efficient Offset Cancellation Current DAC
This paper introduces a pulse oximeter front-end with low-noise area-efficient offset cancellation current digital-to-analog converter (DAC). The proposed offset cancellation current DAC is implemented to cancel the input DC current to improve the effective dynamic range (DR). The current DAC is designed to have low-noise and area-efficient characteristics by applying the dynamic element matching technique and reducing the number of idle current mirror transistors. It can generate a current of up to 256 μA. Due to the offset cancellation of the current DAC, the proposed pulse oximeter has a signal-to-noise ratio of 77.4 dB and an effective DR of 133.3 dB. The pulse oximeter front-end is designed in 0.13 μm CMOS and consumes 307.1 μW from a 1.65 V supply. The figure-of-merit is 0.81 pJ/Sample.