{"title":"一种用于峰值拾取人工耳蜗处理器的超低功耗峰值瞬时检测器","authors":"C. Sawigun, W. Ngamkham, W. Serdijn","doi":"10.1109/BIOCAS.2010.5709611","DOIUrl":null,"url":null,"abstract":"This paper presents the design of a sub-threshold CMOS peak-instant detector to be used in a phase-locking peak-picking (PL-PP) bionic ear (BE) processor. The detector is formed by a current sample and hold circuit and a voltage comparator to perform the detection of occurrences of maximum and minimum values of the input. Circuit simulation results using CMOS 0.35 μm AMIS technology confirm that the proposed detector can be operated from a 1.2 V supply and consumes less than 1μW static power for detecting a 5kHz input signal (maximum frequency of the processor). For lower input frequencies the power consumption can be scaled down to further reduce the BE processor's power consumption.","PeriodicalId":440499,"journal":{"name":"2010 Biomedical Circuits and Systems Conference (BioCAS)","volume":"10 5","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"An ultra low-power peak-instant detector for a peak picking cochlear implant processor\",\"authors\":\"C. Sawigun, W. Ngamkham, W. Serdijn\",\"doi\":\"10.1109/BIOCAS.2010.5709611\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the design of a sub-threshold CMOS peak-instant detector to be used in a phase-locking peak-picking (PL-PP) bionic ear (BE) processor. The detector is formed by a current sample and hold circuit and a voltage comparator to perform the detection of occurrences of maximum and minimum values of the input. Circuit simulation results using CMOS 0.35 μm AMIS technology confirm that the proposed detector can be operated from a 1.2 V supply and consumes less than 1μW static power for detecting a 5kHz input signal (maximum frequency of the processor). For lower input frequencies the power consumption can be scaled down to further reduce the BE processor's power consumption.\",\"PeriodicalId\":440499,\"journal\":{\"name\":\"2010 Biomedical Circuits and Systems Conference (BioCAS)\",\"volume\":\"10 5\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 Biomedical Circuits and Systems Conference (BioCAS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BIOCAS.2010.5709611\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 Biomedical Circuits and Systems Conference (BioCAS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIOCAS.2010.5709611","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
An ultra low-power peak-instant detector for a peak picking cochlear implant processor
This paper presents the design of a sub-threshold CMOS peak-instant detector to be used in a phase-locking peak-picking (PL-PP) bionic ear (BE) processor. The detector is formed by a current sample and hold circuit and a voltage comparator to perform the detection of occurrences of maximum and minimum values of the input. Circuit simulation results using CMOS 0.35 μm AMIS technology confirm that the proposed detector can be operated from a 1.2 V supply and consumes less than 1μW static power for detecting a 5kHz input signal (maximum frequency of the processor). For lower input frequencies the power consumption can be scaled down to further reduce the BE processor's power consumption.