{"title":"便携式输液泵,可编程16率。","authors":"J Bojsen, K Kølendorf, F Haslev, K Jørgensen","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>An external, portable, programmable infusion pump has been developed for long-term therapeutic intravenous infusion of drugs. The impulse-controlled system consists of a 250 g CMOS-electronic unit, and an electromechanical infuser (250 g) containing a 10-ml disposable syringe. The infusion rate pattern is manually preprogrammed from 24 to 384 microliter/0.5 h. The coefficient of variation of the volume infused is less than 2% per. 0.5 h. The system has been tested by continuous administration of insulin in diabetics during 4 consecutive days, and can operate for 6-7 days with a 1 Ah, 5.4 V battery. The mean capillary blood glucose concentration could be maintained at levels close to normal (i.e. 7.0 mmol/1 +/- 2.3 (SD)) during the treatment period.</p>","PeriodicalId":75603,"journal":{"name":"Biotelemetry and patient monitoring","volume":"5 3","pages":"123-33"},"PeriodicalIF":0.0000,"publicationDate":"1978-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A portable infusion pump, programmable with 16 rates.\",\"authors\":\"J Bojsen, K Kølendorf, F Haslev, K Jørgensen\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>An external, portable, programmable infusion pump has been developed for long-term therapeutic intravenous infusion of drugs. The impulse-controlled system consists of a 250 g CMOS-electronic unit, and an electromechanical infuser (250 g) containing a 10-ml disposable syringe. The infusion rate pattern is manually preprogrammed from 24 to 384 microliter/0.5 h. The coefficient of variation of the volume infused is less than 2% per. 0.5 h. The system has been tested by continuous administration of insulin in diabetics during 4 consecutive days, and can operate for 6-7 days with a 1 Ah, 5.4 V battery. The mean capillary blood glucose concentration could be maintained at levels close to normal (i.e. 7.0 mmol/1 +/- 2.3 (SD)) during the treatment period.</p>\",\"PeriodicalId\":75603,\"journal\":{\"name\":\"Biotelemetry and patient monitoring\",\"volume\":\"5 3\",\"pages\":\"123-33\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1978-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biotelemetry and patient monitoring\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biotelemetry and patient monitoring","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A portable infusion pump, programmable with 16 rates.
An external, portable, programmable infusion pump has been developed for long-term therapeutic intravenous infusion of drugs. The impulse-controlled system consists of a 250 g CMOS-electronic unit, and an electromechanical infuser (250 g) containing a 10-ml disposable syringe. The infusion rate pattern is manually preprogrammed from 24 to 384 microliter/0.5 h. The coefficient of variation of the volume infused is less than 2% per. 0.5 h. The system has been tested by continuous administration of insulin in diabetics during 4 consecutive days, and can operate for 6-7 days with a 1 Ah, 5.4 V battery. The mean capillary blood glucose concentration could be maintained at levels close to normal (i.e. 7.0 mmol/1 +/- 2.3 (SD)) during the treatment period.