用于新生儿连续氧监测的皮肤传感器。

Biotelemetry Pub Date : 1977-01-01
P Eberhard, W Mindt
{"title":"用于新生儿连续氧监测的皮肤传感器。","authors":"P Eberhard,&nbsp;W Mindt","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Since the introduction of the technique of cutaneous1 pO2 measurement by directly heated oxygen sensors in 1972, the clinical applications and limitations of this new method have been extensively investigated. The method has proven to be of particular value in monitoring of high risk newborns as it affords the possibility of continuously monitoring clinically significant changes in the oxygenation state of the newborn. In this paper, methodological criteria for the assessment of the reliability of cutaneous pO2 monitoring are discussed. Particular consideration is given to the oxygen and temperature profiles in the vicinity of the skin sensor and to the response time of the sensor. In view of the fact that the cutaneous pO2 reflects the oxygen partial pressure at the level of arterialized cutaneous tissue, the method has limitations if it is used as an indirect determinant of arterial pO2.</p>","PeriodicalId":75602,"journal":{"name":"Biotelemetry","volume":"4 2","pages":"48-76"},"PeriodicalIF":0.0000,"publicationDate":"1977-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Skin sensors for continuous oxygen monitoring of newborns.\",\"authors\":\"P Eberhard,&nbsp;W Mindt\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Since the introduction of the technique of cutaneous1 pO2 measurement by directly heated oxygen sensors in 1972, the clinical applications and limitations of this new method have been extensively investigated. The method has proven to be of particular value in monitoring of high risk newborns as it affords the possibility of continuously monitoring clinically significant changes in the oxygenation state of the newborn. In this paper, methodological criteria for the assessment of the reliability of cutaneous pO2 monitoring are discussed. Particular consideration is given to the oxygen and temperature profiles in the vicinity of the skin sensor and to the response time of the sensor. In view of the fact that the cutaneous pO2 reflects the oxygen partial pressure at the level of arterialized cutaneous tissue, the method has limitations if it is used as an indirect determinant of arterial pO2.</p>\",\"PeriodicalId\":75602,\"journal\":{\"name\":\"Biotelemetry\",\"volume\":\"4 2\",\"pages\":\"48-76\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1977-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biotelemetry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biotelemetry","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

自1972年采用直接加热氧传感器测量皮肤pO2以来,人们对这种新方法的临床应用和局限性进行了广泛的研究。该方法已被证明在监测高危新生儿中具有特别的价值,因为它提供了连续监测新生儿氧合状态临床显著变化的可能性。本文讨论了评估皮肤pO2监测可靠性的方法学标准。特别考虑了皮肤传感器附近的氧气和温度分布以及传感器的响应时间。鉴于皮肤pO2反映动脉化皮肤组织水平上的氧分压,如果将该方法用作动脉pO2的间接决定因素,则该方法具有局限性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Skin sensors for continuous oxygen monitoring of newborns.

Since the introduction of the technique of cutaneous1 pO2 measurement by directly heated oxygen sensors in 1972, the clinical applications and limitations of this new method have been extensively investigated. The method has proven to be of particular value in monitoring of high risk newborns as it affords the possibility of continuously monitoring clinically significant changes in the oxygenation state of the newborn. In this paper, methodological criteria for the assessment of the reliability of cutaneous pO2 monitoring are discussed. Particular consideration is given to the oxygen and temperature profiles in the vicinity of the skin sensor and to the response time of the sensor. In view of the fact that the cutaneous pO2 reflects the oxygen partial pressure at the level of arterialized cutaneous tissue, the method has limitations if it is used as an indirect determinant of arterial pO2.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信