{"title":"[动脉端到端吻合螺钉密集固定环(作者图)]。","authors":"P H Schomacher","doi":"10.1055/s-0028-1097072","DOIUrl":null,"url":null,"abstract":"<p><p>In study of screw-dense-fixation-ring method in 15 cases of a dog's femoral artery, end to end, was reconstructed. The anastomoses is achieved by vessels of 3 - 6 mm diameter. Within a period of 1 - 6 months post-operatively, average of 3 months, angiographic control of all cases showed no complications such as aneurysm or stricture. The construction of screw-dense-fixation-ring seems to give a considerable result, because the power which is keeping the rings together, can be controlled.</p>","PeriodicalId":22981,"journal":{"name":"Thoraxchirurgie, vaskulare Chirurgie","volume":"25 6","pages":"422-6"},"PeriodicalIF":0.0000,"publicationDate":"1977-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1055/s-0028-1097072","citationCount":"0","resultStr":"{\"title\":\"[Artery end to end anastomoses with screw-dense-fixation-rings (author's transl)].\",\"authors\":\"P H Schomacher\",\"doi\":\"10.1055/s-0028-1097072\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In study of screw-dense-fixation-ring method in 15 cases of a dog's femoral artery, end to end, was reconstructed. The anastomoses is achieved by vessels of 3 - 6 mm diameter. Within a period of 1 - 6 months post-operatively, average of 3 months, angiographic control of all cases showed no complications such as aneurysm or stricture. The construction of screw-dense-fixation-ring seems to give a considerable result, because the power which is keeping the rings together, can be controlled.</p>\",\"PeriodicalId\":22981,\"journal\":{\"name\":\"Thoraxchirurgie, vaskulare Chirurgie\",\"volume\":\"25 6\",\"pages\":\"422-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1977-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1055/s-0028-1097072\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Thoraxchirurgie, vaskulare Chirurgie\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1055/s-0028-1097072\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Thoraxchirurgie, vaskulare Chirurgie","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0028-1097072","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
[Artery end to end anastomoses with screw-dense-fixation-rings (author's transl)].
In study of screw-dense-fixation-ring method in 15 cases of a dog's femoral artery, end to end, was reconstructed. The anastomoses is achieved by vessels of 3 - 6 mm diameter. Within a period of 1 - 6 months post-operatively, average of 3 months, angiographic control of all cases showed no complications such as aneurysm or stricture. The construction of screw-dense-fixation-ring seems to give a considerable result, because the power which is keeping the rings together, can be controlled.