{"title":"控制有源滤波器使用源电流检测","authors":"T. Takeshita, N. Matsui","doi":"10.1109/IECON.2003.1280282","DOIUrl":null,"url":null,"abstract":"This paper presents a control scheme of the shunt active filters using the source current detection to suppress the source current harmonics. The proposed control scheme can minimize the source current harmonics under the given active filter capacity, which can be realized by adjusting the magnitude and phase of the compensation current using the complex compensation gains in the frequency domain. The effectiveness of the proposed control scheme has been verified by experiments. As a result, the good effect on the compensation for the source harmonic currents in the proposed control scheme is obtained compared with that in the conventional one.","PeriodicalId":403239,"journal":{"name":"IECON'03. 29th Annual Conference of the IEEE Industrial Electronics Society (IEEE Cat. No.03CH37468)","volume":"150 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-11-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Control of active filters using source current detection\",\"authors\":\"T. Takeshita, N. Matsui\",\"doi\":\"10.1109/IECON.2003.1280282\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a control scheme of the shunt active filters using the source current detection to suppress the source current harmonics. The proposed control scheme can minimize the source current harmonics under the given active filter capacity, which can be realized by adjusting the magnitude and phase of the compensation current using the complex compensation gains in the frequency domain. The effectiveness of the proposed control scheme has been verified by experiments. As a result, the good effect on the compensation for the source harmonic currents in the proposed control scheme is obtained compared with that in the conventional one.\",\"PeriodicalId\":403239,\"journal\":{\"name\":\"IECON'03. 29th Annual Conference of the IEEE Industrial Electronics Society (IEEE Cat. No.03CH37468)\",\"volume\":\"150 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-11-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IECON'03. 29th Annual Conference of the IEEE Industrial Electronics Society (IEEE Cat. No.03CH37468)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IECON.2003.1280282\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IECON'03. 29th Annual Conference of the IEEE Industrial Electronics Society (IEEE Cat. No.03CH37468)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IECON.2003.1280282","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Control of active filters using source current detection
This paper presents a control scheme of the shunt active filters using the source current detection to suppress the source current harmonics. The proposed control scheme can minimize the source current harmonics under the given active filter capacity, which can be realized by adjusting the magnitude and phase of the compensation current using the complex compensation gains in the frequency domain. The effectiveness of the proposed control scheme has been verified by experiments. As a result, the good effect on the compensation for the source harmonic currents in the proposed control scheme is obtained compared with that in the conventional one.