10kw三相并网背靠背逆变器的设计与控制

Woei-Luen Chen, Chun-Yuan Chen, I-Chyn Wey, Yu-Ping Chou
{"title":"10kw三相并网背靠背逆变器的设计与控制","authors":"Woei-Luen Chen, Chun-Yuan Chen, I-Chyn Wey, Yu-Ping Chou","doi":"10.1109/QIR.2017.8168497","DOIUrl":null,"url":null,"abstract":"Inverters in back to back (B2B) connection are utilized to convert the voltage and frequency of the power source to another format. Typical application of inverters is the wind power system. This study presents a B2B inverter for equal voltage and frequency format conversion in which one inverter works to get power from the grid to charge the DC capacitor and another inverter returns most of the active power back to the grid and retain a few powers to maintain the DC-link voltage. The power grid affords only the power loss of the inverters, which benefits the test of the inverter rated above 10kW under general distribution line. A proportional-resonant (PR) controller in a stationary frame in place of a proportional-integral (PI) controller in a synchronous frame was adopted to condition the B2B inverter AC current for grid connection due to the advantages such as instantaneous tracking capability as well as low-cost computational resources. To mitigate the startup transient for grid connection, the instantaneous grid voltage was feedforwarded to the inverter voltage command. The B2B inverter was run according to the proposed control strategy under various conditions such as the reactive power control and the active and reactive power controls. Experimental results show that the power returns to the power grid is close to originally put in and the proposed B2B inverter can be tested under the distribution line with the power capability over 10kW.","PeriodicalId":225743,"journal":{"name":"2017 15th International Conference on Quality in Research (QiR) : International Symposium on Electrical and Computer Engineering","volume":"39 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design and control of a 10kw three-phase grid-tied back to back inverter\",\"authors\":\"Woei-Luen Chen, Chun-Yuan Chen, I-Chyn Wey, Yu-Ping Chou\",\"doi\":\"10.1109/QIR.2017.8168497\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Inverters in back to back (B2B) connection are utilized to convert the voltage and frequency of the power source to another format. Typical application of inverters is the wind power system. This study presents a B2B inverter for equal voltage and frequency format conversion in which one inverter works to get power from the grid to charge the DC capacitor and another inverter returns most of the active power back to the grid and retain a few powers to maintain the DC-link voltage. The power grid affords only the power loss of the inverters, which benefits the test of the inverter rated above 10kW under general distribution line. A proportional-resonant (PR) controller in a stationary frame in place of a proportional-integral (PI) controller in a synchronous frame was adopted to condition the B2B inverter AC current for grid connection due to the advantages such as instantaneous tracking capability as well as low-cost computational resources. To mitigate the startup transient for grid connection, the instantaneous grid voltage was feedforwarded to the inverter voltage command. The B2B inverter was run according to the proposed control strategy under various conditions such as the reactive power control and the active and reactive power controls. Experimental results show that the power returns to the power grid is close to originally put in and the proposed B2B inverter can be tested under the distribution line with the power capability over 10kW.\",\"PeriodicalId\":225743,\"journal\":{\"name\":\"2017 15th International Conference on Quality in Research (QiR) : International Symposium on Electrical and Computer Engineering\",\"volume\":\"39 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 15th International Conference on Quality in Research (QiR) : International Symposium on Electrical and Computer Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/QIR.2017.8168497\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 15th International Conference on Quality in Research (QiR) : International Symposium on Electrical and Computer Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/QIR.2017.8168497","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

利用背靠背(B2B)连接中的逆变器将电源的电压和频率转换为另一种格式。逆变器的典型应用是风力发电系统。本研究提出了一种等电压、等频率格式转换的B2B逆变器,其中一个逆变器从电网获取电力给直流电容器充电,另一个逆变器将大部分有功功率返回电网,并保留少量功率维持直流电压。电网只承担逆变器的功率损耗,有利于在总配电线路下测试额定功率在10kW以上的逆变器。采用固定框架中的比例谐振(PR)控制器代替同步框架中的比例积分(PI)控制器来调节B2B逆变器的交流并网电流,具有瞬时跟踪能力和计算资源低的优点。为了缓解并网时的启动暂态,将电网瞬时电压反馈给逆变器电压指令。根据所提出的控制策略,B2B逆变器在无功控制、有功和无功控制等多种工况下运行。实验结果表明,返回电网的功率与输入功率接近,所设计的B2B逆变器可以在配电网下进行测试,功率容量大于10kW。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design and control of a 10kw three-phase grid-tied back to back inverter
Inverters in back to back (B2B) connection are utilized to convert the voltage and frequency of the power source to another format. Typical application of inverters is the wind power system. This study presents a B2B inverter for equal voltage and frequency format conversion in which one inverter works to get power from the grid to charge the DC capacitor and another inverter returns most of the active power back to the grid and retain a few powers to maintain the DC-link voltage. The power grid affords only the power loss of the inverters, which benefits the test of the inverter rated above 10kW under general distribution line. A proportional-resonant (PR) controller in a stationary frame in place of a proportional-integral (PI) controller in a synchronous frame was adopted to condition the B2B inverter AC current for grid connection due to the advantages such as instantaneous tracking capability as well as low-cost computational resources. To mitigate the startup transient for grid connection, the instantaneous grid voltage was feedforwarded to the inverter voltage command. The B2B inverter was run according to the proposed control strategy under various conditions such as the reactive power control and the active and reactive power controls. Experimental results show that the power returns to the power grid is close to originally put in and the proposed B2B inverter can be tested under the distribution line with the power capability over 10kW.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信