发电机-励磁机组合系统的效率与性能分析

H. Woo, Dong-Hee Lee
{"title":"发电机-励磁机组合系统的效率与性能分析","authors":"H. Woo, Dong-Hee Lee","doi":"10.1109/ICCEP.2019.8890118","DOIUrl":null,"url":null,"abstract":"This paper presents a performance analysis of a generator-exciter combination system that implements both generator and exciter structures. In practical applications, permanent magnets (PMs) are commonly used in generators and exciters. The adaptation of PMs in wound generators or exciters creates the so-called hybrid structure. Three types of exciter that can be used for field excitation of the main generator are compared and their efficiency, along with the respective dynamic response, are analyzed. In order to improve the dynamic response and operating efficiency, a parallel hybrid generator and a PM exciter with a directly embedded field current controller are presented in this paper. Finite element analysis (FEA) was performed to find out the characteristics of the structure. Finally, the effectiveness of the proposed hybrid generator system and the accuracy of the analysis results are confirmed through simulation and experiments.","PeriodicalId":277718,"journal":{"name":"2019 International Conference on Clean Electrical Power (ICCEP)","volume":"187 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Efficiency and Performance Analysis of a Generator – Exciter Combination System\",\"authors\":\"H. Woo, Dong-Hee Lee\",\"doi\":\"10.1109/ICCEP.2019.8890118\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a performance analysis of a generator-exciter combination system that implements both generator and exciter structures. In practical applications, permanent magnets (PMs) are commonly used in generators and exciters. The adaptation of PMs in wound generators or exciters creates the so-called hybrid structure. Three types of exciter that can be used for field excitation of the main generator are compared and their efficiency, along with the respective dynamic response, are analyzed. In order to improve the dynamic response and operating efficiency, a parallel hybrid generator and a PM exciter with a directly embedded field current controller are presented in this paper. Finite element analysis (FEA) was performed to find out the characteristics of the structure. Finally, the effectiveness of the proposed hybrid generator system and the accuracy of the analysis results are confirmed through simulation and experiments.\",\"PeriodicalId\":277718,\"journal\":{\"name\":\"2019 International Conference on Clean Electrical Power (ICCEP)\",\"volume\":\"187 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 International Conference on Clean Electrical Power (ICCEP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICCEP.2019.8890118\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International Conference on Clean Electrical Power (ICCEP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCEP.2019.8890118","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了一种同时实现发电机和励磁器结构的发电机-励磁器组合系统的性能分析。在实际应用中,永磁体通常用于发电机和励磁器。在绕线发电机或励磁器中采用pm产生了所谓的混合结构。对可用于主发电机励磁的三种励磁器进行了比较,分析了它们的励磁效率和各自的动态响应。为了提高动态响应和运行效率,本文提出了一种并联混合发电机和带直接嵌入式励磁电流控制器的永磁励磁器。对结构进行了有限元分析(FEA)。最后,通过仿真和实验验证了所提混合发电系统的有效性和分析结果的准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Efficiency and Performance Analysis of a Generator – Exciter Combination System
This paper presents a performance analysis of a generator-exciter combination system that implements both generator and exciter structures. In practical applications, permanent magnets (PMs) are commonly used in generators and exciters. The adaptation of PMs in wound generators or exciters creates the so-called hybrid structure. Three types of exciter that can be used for field excitation of the main generator are compared and their efficiency, along with the respective dynamic response, are analyzed. In order to improve the dynamic response and operating efficiency, a parallel hybrid generator and a PM exciter with a directly embedded field current controller are presented in this paper. Finite element analysis (FEA) was performed to find out the characteristics of the structure. Finally, the effectiveness of the proposed hybrid generator system and the accuracy of the analysis results are confirmed through simulation and experiments.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信