多气隙覆冰绝缘子的闪络建模

J. Zhang, M. Farzaneh
{"title":"多气隙覆冰绝缘子的闪络建模","authors":"J. Zhang, M. Farzaneh","doi":"10.1109/TDC.2006.1668468","DOIUrl":null,"url":null,"abstract":"Using a standard porcelain post insulator, the flashover process on an ice surface was simulated and analyzed. Based on the experimental results, a mathematical model for predicting the critical flashover voltage of ice-covered insulators with multi-arcs is presented. The model was applied to a post insulator with a dry arcing distance of 4.17 m, corresponding to the full-scale insulator string used in the Hydro-Quebec 735 kV substations. It was found there is good agreement between the experimental results and those from the mathematical model. The results obtained are helpful for properly selecting the insulators used in cold climate regions","PeriodicalId":123024,"journal":{"name":"2005/2006 IEEE/PES Transmission and Distribution Conference and Exhibition","volume":"115 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Modeling of Flashover on Ice-Covered Insulators with Multi Air Gaps\",\"authors\":\"J. Zhang, M. Farzaneh\",\"doi\":\"10.1109/TDC.2006.1668468\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Using a standard porcelain post insulator, the flashover process on an ice surface was simulated and analyzed. Based on the experimental results, a mathematical model for predicting the critical flashover voltage of ice-covered insulators with multi-arcs is presented. The model was applied to a post insulator with a dry arcing distance of 4.17 m, corresponding to the full-scale insulator string used in the Hydro-Quebec 735 kV substations. It was found there is good agreement between the experimental results and those from the mathematical model. The results obtained are helpful for properly selecting the insulators used in cold climate regions\",\"PeriodicalId\":123024,\"journal\":{\"name\":\"2005/2006 IEEE/PES Transmission and Distribution Conference and Exhibition\",\"volume\":\"115 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-05-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2005/2006 IEEE/PES Transmission and Distribution Conference and Exhibition\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TDC.2006.1668468\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2005/2006 IEEE/PES Transmission and Distribution Conference and Exhibition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TDC.2006.1668468","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

采用标准瓷柱绝缘子,对冰面上的闪络过程进行了模拟和分析。在实验结果的基础上,建立了多弧覆冰绝缘子临界闪络电压的数学模型。该模型应用于干弧距离为4.17 m的柱式绝缘子,对应于魁北克水电公司735 kV变电站中使用的全尺寸绝缘子串。实验结果与数学模型计算结果吻合较好。所得结果有助于在寒冷气候地区合理选用绝缘子
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Modeling of Flashover on Ice-Covered Insulators with Multi Air Gaps
Using a standard porcelain post insulator, the flashover process on an ice surface was simulated and analyzed. Based on the experimental results, a mathematical model for predicting the critical flashover voltage of ice-covered insulators with multi-arcs is presented. The model was applied to a post insulator with a dry arcing distance of 4.17 m, corresponding to the full-scale insulator string used in the Hydro-Quebec 735 kV substations. It was found there is good agreement between the experimental results and those from the mathematical model. The results obtained are helpful for properly selecting the insulators used in cold climate regions
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信