考虑土壤参数频率依赖性的雷击过电压峰值:优势频率与雷击电流前时间相关的新方法

Rodolfo A. R. Moura, D. Mestriner, R. Procopio, M. Schroeder, F. A. Assis, F. Delfino
{"title":"考虑土壤参数频率依赖性的雷击过电压峰值:优势频率与雷击电流前时间相关的新方法","authors":"Rodolfo A. R. Moura, D. Mestriner, R. Procopio, M. Schroeder, F. A. Assis, F. Delfino","doi":"10.1109/ICHQP53011.2022.9808740","DOIUrl":null,"url":null,"abstract":"For the study of lightning performance of distribution lines, the correct assessment of indirect flashes plays an important role. Thus, this paper considers the frequency-dependent soil electrical parameters in a previously developed approximate formula for the peak value of lightning-induced overvoltage on overhead lines. This approach consists of using a specific frequency (based on the lightning front time) to estimate the ground conductivity. Since the proposal is easy to implement and fast to run in any computational environment, it is a practical engineering tool. According to the results, it is possible to note the importance of applying models that take into account the variation of soil parameters with frequency, since overvoltage reductions for high resistivity soils above 35% were verified.","PeriodicalId":249133,"journal":{"name":"2022 20th International Conference on Harmonics & Quality of Power (ICHQP)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Lightning-Induced Overvoltage Peaks Considering Soil Parameters Frequency-Dependence: New Approach with Dominant Frequency Associated with Lightning Current Front Time\",\"authors\":\"Rodolfo A. R. Moura, D. Mestriner, R. Procopio, M. Schroeder, F. A. Assis, F. Delfino\",\"doi\":\"10.1109/ICHQP53011.2022.9808740\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"For the study of lightning performance of distribution lines, the correct assessment of indirect flashes plays an important role. Thus, this paper considers the frequency-dependent soil electrical parameters in a previously developed approximate formula for the peak value of lightning-induced overvoltage on overhead lines. This approach consists of using a specific frequency (based on the lightning front time) to estimate the ground conductivity. Since the proposal is easy to implement and fast to run in any computational environment, it is a practical engineering tool. According to the results, it is possible to note the importance of applying models that take into account the variation of soil parameters with frequency, since overvoltage reductions for high resistivity soils above 35% were verified.\",\"PeriodicalId\":249133,\"journal\":{\"name\":\"2022 20th International Conference on Harmonics & Quality of Power (ICHQP)\",\"volume\":\"17 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-05-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 20th International Conference on Harmonics & Quality of Power (ICHQP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHQP53011.2022.9808740\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 20th International Conference on Harmonics & Quality of Power (ICHQP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHQP53011.2022.9808740","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

对于配电线路雷电性能的研究,正确评估间接闪电具有重要意义。因此,本文在先前开发的架空线路雷击过电压峰值近似公式中考虑了与频率相关的土壤电参数。这种方法包括使用特定频率(基于闪电前时间)来估计地面电导率。由于该方案易于实现,并且可以在任何计算环境中快速运行,因此是一种实用的工程工具。根据结果,可以注意到应用考虑土壤参数随频率变化的模型的重要性,因为验证了35%以上的高电阻率土壤过电压降低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Lightning-Induced Overvoltage Peaks Considering Soil Parameters Frequency-Dependence: New Approach with Dominant Frequency Associated with Lightning Current Front Time
For the study of lightning performance of distribution lines, the correct assessment of indirect flashes plays an important role. Thus, this paper considers the frequency-dependent soil electrical parameters in a previously developed approximate formula for the peak value of lightning-induced overvoltage on overhead lines. This approach consists of using a specific frequency (based on the lightning front time) to estimate the ground conductivity. Since the proposal is easy to implement and fast to run in any computational environment, it is a practical engineering tool. According to the results, it is possible to note the importance of applying models that take into account the variation of soil parameters with frequency, since overvoltage reductions for high resistivity soils above 35% were verified.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信