电磁聚焦电子枪在YAG投影CRT中的应用

Wang Jun, Zhou Min, Chen Jianbo, Ran Qijun
{"title":"电磁聚焦电子枪在YAG投影CRT中的应用","authors":"Wang Jun, Zhou Min, Chen Jianbo, Ran Qijun","doi":"10.1109/ASID.1999.762730","DOIUrl":null,"url":null,"abstract":"An electromagnetic focusing electron gun was used in high-luminance and high-definition YAG (yttrium aluminum garnet) projection CRT successfully. The dual-focusing system in it was developed, which was composed of electrostatic pre-focusing lens and electromagnetic focusing lens. Result from the special optimization of structure and voltage, the electron gun has excellent characteristics especially with high current. As a result, on the green YAG phosphor screen, beam spot diameters of 0.065-0.080 mm at cathode currents of 0.5-1.0 mA. So the horizontal resolution was more than 1200 TV-lines on the 3-in projection CRT screen. Meanwhile, the luminance of 1.4/spl times/10/sup 5/ cd/m/sup 2/ at cathode current of 1.0 mA and anode voltage of 29 kv was achieved.","PeriodicalId":170859,"journal":{"name":"Proceedings of 5th Asian Symposium on Information Display. ASID '99 (IEEE Cat. No.99EX291)","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-03-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Application of electromagnetic focusing electron gun in YAG projection CRT\",\"authors\":\"Wang Jun, Zhou Min, Chen Jianbo, Ran Qijun\",\"doi\":\"10.1109/ASID.1999.762730\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An electromagnetic focusing electron gun was used in high-luminance and high-definition YAG (yttrium aluminum garnet) projection CRT successfully. The dual-focusing system in it was developed, which was composed of electrostatic pre-focusing lens and electromagnetic focusing lens. Result from the special optimization of structure and voltage, the electron gun has excellent characteristics especially with high current. As a result, on the green YAG phosphor screen, beam spot diameters of 0.065-0.080 mm at cathode currents of 0.5-1.0 mA. So the horizontal resolution was more than 1200 TV-lines on the 3-in projection CRT screen. Meanwhile, the luminance of 1.4/spl times/10/sup 5/ cd/m/sup 2/ at cathode current of 1.0 mA and anode voltage of 29 kv was achieved.\",\"PeriodicalId\":170859,\"journal\":{\"name\":\"Proceedings of 5th Asian Symposium on Information Display. ASID '99 (IEEE Cat. No.99EX291)\",\"volume\":\"31 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-03-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of 5th Asian Symposium on Information Display. ASID '99 (IEEE Cat. No.99EX291)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ASID.1999.762730\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 5th Asian Symposium on Information Display. ASID '99 (IEEE Cat. No.99EX291)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ASID.1999.762730","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

将电磁聚焦电子枪成功地应用于高亮度、高清晰度YAG(钇铝石榴石)投影CRT。研制了由静电预聚焦透镜和电磁聚焦透镜组成的双聚焦系统。由于对结构和电压进行了特殊的优化,使电子枪具有优异的性能,特别是大电流性能。因此,在绿色YAG荧光粉屏幕上,阴极电流为0.5-1.0 mA时,束斑直径为0.065-0.080 mm。因此,在3英寸投影CRT屏幕上,水平分辨率超过1200电视线。同时,在阴极电流为1.0 mA,阳极电压为29 kv时,其亮度达到1.4/spl倍/10/sup 5/ cd/m/sup 2/。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Application of electromagnetic focusing electron gun in YAG projection CRT
An electromagnetic focusing electron gun was used in high-luminance and high-definition YAG (yttrium aluminum garnet) projection CRT successfully. The dual-focusing system in it was developed, which was composed of electrostatic pre-focusing lens and electromagnetic focusing lens. Result from the special optimization of structure and voltage, the electron gun has excellent characteristics especially with high current. As a result, on the green YAG phosphor screen, beam spot diameters of 0.065-0.080 mm at cathode currents of 0.5-1.0 mA. So the horizontal resolution was more than 1200 TV-lines on the 3-in projection CRT screen. Meanwhile, the luminance of 1.4/spl times/10/sup 5/ cd/m/sup 2/ at cathode current of 1.0 mA and anode voltage of 29 kv was achieved.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信