并联输电线路在维护状态下互阻抗效应的实例研究

K. Mangunkusumo, A. A. Kusuma, B. S. Munir
{"title":"并联输电线路在维护状态下互阻抗效应的实例研究","authors":"K. Mangunkusumo, A. A. Kusuma, B. S. Munir","doi":"10.1109/ICITEED.2018.8534740","DOIUrl":null,"url":null,"abstract":"Parallel lines are utilized to enhance the reliability and security of energy. Mutual impedance arises when transmission lines are parallel lines on a common right way. In this study, a system model to observed mutual impedance effect between parallel disrupted lines and under maintenance line are explained. The system model is validated using actual recorded fault current waveform. The simulation result shows that when disconnector of the under maintenance line open and grounded on both side, the line mutual current will be high. On the other hand, when disconnector open and gorunded only on one side, the line mutual current will be low but the voltage will be high.","PeriodicalId":142523,"journal":{"name":"2018 10th International Conference on Information Technology and Electrical Engineering (ICITEE)","volume":"82 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"A Case Study of Mutual Impedance Effect in Parallel Transmission Lines Under Maintenance Condition\",\"authors\":\"K. Mangunkusumo, A. A. Kusuma, B. S. Munir\",\"doi\":\"10.1109/ICITEED.2018.8534740\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Parallel lines are utilized to enhance the reliability and security of energy. Mutual impedance arises when transmission lines are parallel lines on a common right way. In this study, a system model to observed mutual impedance effect between parallel disrupted lines and under maintenance line are explained. The system model is validated using actual recorded fault current waveform. The simulation result shows that when disconnector of the under maintenance line open and grounded on both side, the line mutual current will be high. On the other hand, when disconnector open and gorunded only on one side, the line mutual current will be low but the voltage will be high.\",\"PeriodicalId\":142523,\"journal\":{\"name\":\"2018 10th International Conference on Information Technology and Electrical Engineering (ICITEE)\",\"volume\":\"82 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 10th International Conference on Information Technology and Electrical Engineering (ICITEE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICITEED.2018.8534740\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 10th International Conference on Information Technology and Electrical Engineering (ICITEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICITEED.2018.8534740","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

平行线被用来提高能源的可靠性和安全性。当传输线是在公共正确方向上的平行线时,就会产生相互阻抗。本文建立了一个系统模型,用于观察平行断线和欠维护线之间的互阻抗效应。利用实际记录的故障电流波形对系统模型进行了验证。仿真结果表明,当下维护线路的隔离开关断开并两侧接地时,线路互电流较大。另一方面,当隔离开关打开并只在一侧闭合时,线路相互电流会很低,但电压会很高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Case Study of Mutual Impedance Effect in Parallel Transmission Lines Under Maintenance Condition
Parallel lines are utilized to enhance the reliability and security of energy. Mutual impedance arises when transmission lines are parallel lines on a common right way. In this study, a system model to observed mutual impedance effect between parallel disrupted lines and under maintenance line are explained. The system model is validated using actual recorded fault current waveform. The simulation result shows that when disconnector of the under maintenance line open and grounded on both side, the line mutual current will be high. On the other hand, when disconnector open and gorunded only on one side, the line mutual current will be low but the voltage will be high.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信