Mustafa A. Kadhim, Yaser Al-Anii, N. Kapur, J. Summers, H. Thompson
{"title":"直接液冷服务器混合模式空气处理机组的性能","authors":"Mustafa A. Kadhim, Yaser Al-Anii, N. Kapur, J. Summers, H. Thompson","doi":"10.1109/SEMI-THERM.2017.7896926","DOIUrl":null,"url":null,"abstract":"Datacenter energy consumption constitutes a large portion of global energy consumption. Particularly, a large amount of this energy is consumed by the datacenter cooling system. Subsequently, many innovative cooling technologies have been developed to reduce energy consumption and increase cooling performance. In this work, an experimental setup was designed and constructed which comprises a direct liquid-cooled server, rack-level cooling and compressor-free external cooling system. This study tracks the heat generated from IT processes to the environment. In addition, the power usage effectiveness (PUE) and the air handling unit (AHU) performance are investigated. The objectives were studied under different datacenter operation scenarios, and AHU configurations.","PeriodicalId":442782,"journal":{"name":"2017 33rd Thermal Measurement, Modeling & Management Symposium (SEMI-THERM)","volume":"42 3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Performance of a mixed mode air handling unit for direct liquid-cooled servers\",\"authors\":\"Mustafa A. Kadhim, Yaser Al-Anii, N. Kapur, J. Summers, H. Thompson\",\"doi\":\"10.1109/SEMI-THERM.2017.7896926\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Datacenter energy consumption constitutes a large portion of global energy consumption. Particularly, a large amount of this energy is consumed by the datacenter cooling system. Subsequently, many innovative cooling technologies have been developed to reduce energy consumption and increase cooling performance. In this work, an experimental setup was designed and constructed which comprises a direct liquid-cooled server, rack-level cooling and compressor-free external cooling system. This study tracks the heat generated from IT processes to the environment. In addition, the power usage effectiveness (PUE) and the air handling unit (AHU) performance are investigated. The objectives were studied under different datacenter operation scenarios, and AHU configurations.\",\"PeriodicalId\":442782,\"journal\":{\"name\":\"2017 33rd Thermal Measurement, Modeling & Management Symposium (SEMI-THERM)\",\"volume\":\"42 3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-04-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 33rd Thermal Measurement, Modeling & Management Symposium (SEMI-THERM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SEMI-THERM.2017.7896926\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 33rd Thermal Measurement, Modeling & Management Symposium (SEMI-THERM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SEMI-THERM.2017.7896926","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Performance of a mixed mode air handling unit for direct liquid-cooled servers
Datacenter energy consumption constitutes a large portion of global energy consumption. Particularly, a large amount of this energy is consumed by the datacenter cooling system. Subsequently, many innovative cooling technologies have been developed to reduce energy consumption and increase cooling performance. In this work, an experimental setup was designed and constructed which comprises a direct liquid-cooled server, rack-level cooling and compressor-free external cooling system. This study tracks the heat generated from IT processes to the environment. In addition, the power usage effectiveness (PUE) and the air handling unit (AHU) performance are investigated. The objectives were studied under different datacenter operation scenarios, and AHU configurations.