非线性负载电流下变压器动态负载能力评估

M. Savaghebi, A. Gholami, A. Jalilian
{"title":"非线性负载电流下变压器动态负载能力评估","authors":"M. Savaghebi, A. Gholami, A. Jalilian","doi":"10.1109/UPEC.2008.4651612","DOIUrl":null,"url":null,"abstract":"The portion of the loads which cause harmonic currents is increasing due to the rising prevalence of power electronic components. The use of these loads has increased the awareness of the potential risks due to the transformer overheating. Nowadays, it is well-known that the transformer loading must be restricted for safe operation under non-linear load currents. Conventionally, IEEE C57.110-1998 standard has been applied to give a conservative estimate of loading capability of transformer in this condition. In this paper, the problem of oil-immersed transformer loading capability determination considering nonlinear loads is addressed. A thermal model which considers non-sinusoidal load current is used. Then, the procedure of transformer dynamic and steady state loading capability assessment is described and applied to a power transformer. Comparison of the results of the proposed and conventional methods shows the possibility of transformer loading beyond the limit calculated using conventional method. Finally, an economic analysis is carried out considering two methods.","PeriodicalId":287461,"journal":{"name":"2008 43rd International Universities Power Engineering Conference","volume":"110 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-12-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Transformer dynamic loading capability assessment under nonlinear load currents\",\"authors\":\"M. Savaghebi, A. Gholami, A. Jalilian\",\"doi\":\"10.1109/UPEC.2008.4651612\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The portion of the loads which cause harmonic currents is increasing due to the rising prevalence of power electronic components. The use of these loads has increased the awareness of the potential risks due to the transformer overheating. Nowadays, it is well-known that the transformer loading must be restricted for safe operation under non-linear load currents. Conventionally, IEEE C57.110-1998 standard has been applied to give a conservative estimate of loading capability of transformer in this condition. In this paper, the problem of oil-immersed transformer loading capability determination considering nonlinear loads is addressed. A thermal model which considers non-sinusoidal load current is used. Then, the procedure of transformer dynamic and steady state loading capability assessment is described and applied to a power transformer. Comparison of the results of the proposed and conventional methods shows the possibility of transformer loading beyond the limit calculated using conventional method. Finally, an economic analysis is carried out considering two methods.\",\"PeriodicalId\":287461,\"journal\":{\"name\":\"2008 43rd International Universities Power Engineering Conference\",\"volume\":\"110 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-12-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 43rd International Universities Power Engineering Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/UPEC.2008.4651612\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 43rd International Universities Power Engineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/UPEC.2008.4651612","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

由于电力电子元件的日益普及,引起谐波电流的负载部分正在增加。这些负载的使用增加了由于变压器过热的潜在风险的认识。在非线性负载电流下,为了保证变压器的安全运行,必须对变压器的负载进行限制。在这种情况下,通常采用IEEE C57.110-1998标准对变压器的负载能力进行保守估计。本文研究了考虑非线性载荷的油浸式变压器负荷能力确定问题。采用了考虑非正弦负载电流的热模型。然后,介绍了变压器动稳态负荷能力评估方法,并将其应用于某电力变压器。通过与常规方法计算结果的比较,表明了用常规方法计算变压器负荷超出极限的可能性。最后,结合两种方法进行了经济分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Transformer dynamic loading capability assessment under nonlinear load currents
The portion of the loads which cause harmonic currents is increasing due to the rising prevalence of power electronic components. The use of these loads has increased the awareness of the potential risks due to the transformer overheating. Nowadays, it is well-known that the transformer loading must be restricted for safe operation under non-linear load currents. Conventionally, IEEE C57.110-1998 standard has been applied to give a conservative estimate of loading capability of transformer in this condition. In this paper, the problem of oil-immersed transformer loading capability determination considering nonlinear loads is addressed. A thermal model which considers non-sinusoidal load current is used. Then, the procedure of transformer dynamic and steady state loading capability assessment is described and applied to a power transformer. Comparison of the results of the proposed and conventional methods shows the possibility of transformer loading beyond the limit calculated using conventional method. Finally, an economic analysis is carried out considering two methods.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信