{"title":"一种自动有源和负载拉力测量系统","authors":"David, Williams, P. Tasker","doi":"10.1109/HFPSC.2001.962150","DOIUrl":null,"url":null,"abstract":"A fully automated electronic load and source pull measurement system has been developed using standard Agilent ESG Frequency sources. Combined with a vector corrected time-domain waveform measurement system based on the HP-MTA (Microwave Transition Analyser) enabling real time waveform measurements of the current and voltages to be obtained. The system has been validated using measurements performed on a Heterojunction Bipolar Transistor operating in Class B with constant harmonic terminations on the load and source over variations in drive level.","PeriodicalId":129428,"journal":{"name":"6th IEEE High Frequency Postgraduate Colloquium (Cat. No.01TH8574)","volume":"110 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-09-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"40","resultStr":"{\"title\":\"An automated active source and load pull measurement system\",\"authors\":\"David, Williams, P. Tasker\",\"doi\":\"10.1109/HFPSC.2001.962150\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A fully automated electronic load and source pull measurement system has been developed using standard Agilent ESG Frequency sources. Combined with a vector corrected time-domain waveform measurement system based on the HP-MTA (Microwave Transition Analyser) enabling real time waveform measurements of the current and voltages to be obtained. The system has been validated using measurements performed on a Heterojunction Bipolar Transistor operating in Class B with constant harmonic terminations on the load and source over variations in drive level.\",\"PeriodicalId\":129428,\"journal\":{\"name\":\"6th IEEE High Frequency Postgraduate Colloquium (Cat. No.01TH8574)\",\"volume\":\"110 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-09-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"40\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"6th IEEE High Frequency Postgraduate Colloquium (Cat. No.01TH8574)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/HFPSC.2001.962150\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"6th IEEE High Frequency Postgraduate Colloquium (Cat. No.01TH8574)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HFPSC.2001.962150","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
An automated active source and load pull measurement system
A fully automated electronic load and source pull measurement system has been developed using standard Agilent ESG Frequency sources. Combined with a vector corrected time-domain waveform measurement system based on the HP-MTA (Microwave Transition Analyser) enabling real time waveform measurements of the current and voltages to be obtained. The system has been validated using measurements performed on a Heterojunction Bipolar Transistor operating in Class B with constant harmonic terminations on the load and source over variations in drive level.