{"title":"用于动态核极化的高频连续波回旋管的研制","authors":"M. Blank, S. Cauffman, K. Felch, P. Borchard","doi":"10.1109/UkrMW58013.2022.10036954","DOIUrl":null,"url":null,"abstract":"CPI, partnered with Bruker, has been engaged in a long-standing program to develop gyrotrons for Bruker's commercial dynamic nuclear polarization (DNP) enhanced nuclear magnetic resonance (NMR) spectrometers. The Bruker-CPI development program, started more than 15 years ago, has resulted in a family of robust and reliable continuous wave (cw) high-frequency gyrotrons. The design features and measured performance of the Bruker-CPI gyrotrons at 263, 395, 527, and 593 GHz, all of which have demonstrated over 50 W cw output power in high-quality Gaussian beams, will be described.","PeriodicalId":297673,"journal":{"name":"2022 IEEE 2nd Ukrainian Microwave Week (UkrMW)","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-11-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Development of High-Frequency Continuous-Wave Gyrotrons for Dynamic Nuclear Polarization\",\"authors\":\"M. Blank, S. Cauffman, K. Felch, P. Borchard\",\"doi\":\"10.1109/UkrMW58013.2022.10036954\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"CPI, partnered with Bruker, has been engaged in a long-standing program to develop gyrotrons for Bruker's commercial dynamic nuclear polarization (DNP) enhanced nuclear magnetic resonance (NMR) spectrometers. The Bruker-CPI development program, started more than 15 years ago, has resulted in a family of robust and reliable continuous wave (cw) high-frequency gyrotrons. The design features and measured performance of the Bruker-CPI gyrotrons at 263, 395, 527, and 593 GHz, all of which have demonstrated over 50 W cw output power in high-quality Gaussian beams, will be described.\",\"PeriodicalId\":297673,\"journal\":{\"name\":\"2022 IEEE 2nd Ukrainian Microwave Week (UkrMW)\",\"volume\":\"26 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-11-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE 2nd Ukrainian Microwave Week (UkrMW)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/UkrMW58013.2022.10036954\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE 2nd Ukrainian Microwave Week (UkrMW)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/UkrMW58013.2022.10036954","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Development of High-Frequency Continuous-Wave Gyrotrons for Dynamic Nuclear Polarization
CPI, partnered with Bruker, has been engaged in a long-standing program to develop gyrotrons for Bruker's commercial dynamic nuclear polarization (DNP) enhanced nuclear magnetic resonance (NMR) spectrometers. The Bruker-CPI development program, started more than 15 years ago, has resulted in a family of robust and reliable continuous wave (cw) high-frequency gyrotrons. The design features and measured performance of the Bruker-CPI gyrotrons at 263, 395, 527, and 593 GHz, all of which have demonstrated over 50 W cw output power in high-quality Gaussian beams, will be described.