{"title":"具有直流联络线和交直流并联联络线的互联系统负荷频率控制","authors":"S. Bhamidipati, A. Kumar","doi":"10.1109/NAPS.1990.151393","DOIUrl":null,"url":null,"abstract":"The authors examine the effect of DC tie-lines and AC-DC parallel tie-lines in a multi-area interconnected system consisting of hydro and thermal generation units provided with conventional integral controllers. Separate studies were made for each case and results are compared with a pure AC tie-line multi-area system. A conventional integral controller is used for all the studies demonstrated. The DC tie lines and AC-DC parallel tie-lines in an inter-connected power system give much better dynamic performance by bringing all the desired system variables to steady-state faster than in the existing AC tie-line inter-connected systems and quite smoothly. Eigenvalue analysis supports the results.<<ETX>>","PeriodicalId":330083,"journal":{"name":"Proceedings of the Twenty-Second Annual North American Power Symposium","volume":"51 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1990-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":"{\"title\":\"Load frequency control of an inter-connected system with DC tie-lines and AC-DC parallel tie-lines\",\"authors\":\"S. Bhamidipati, A. Kumar\",\"doi\":\"10.1109/NAPS.1990.151393\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The authors examine the effect of DC tie-lines and AC-DC parallel tie-lines in a multi-area interconnected system consisting of hydro and thermal generation units provided with conventional integral controllers. Separate studies were made for each case and results are compared with a pure AC tie-line multi-area system. A conventional integral controller is used for all the studies demonstrated. The DC tie lines and AC-DC parallel tie-lines in an inter-connected power system give much better dynamic performance by bringing all the desired system variables to steady-state faster than in the existing AC tie-line inter-connected systems and quite smoothly. Eigenvalue analysis supports the results.<<ETX>>\",\"PeriodicalId\":330083,\"journal\":{\"name\":\"Proceedings of the Twenty-Second Annual North American Power Symposium\",\"volume\":\"51 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-10-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"12\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Twenty-Second Annual North American Power Symposium\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NAPS.1990.151393\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Twenty-Second Annual North American Power Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NAPS.1990.151393","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Load frequency control of an inter-connected system with DC tie-lines and AC-DC parallel tie-lines
The authors examine the effect of DC tie-lines and AC-DC parallel tie-lines in a multi-area interconnected system consisting of hydro and thermal generation units provided with conventional integral controllers. Separate studies were made for each case and results are compared with a pure AC tie-line multi-area system. A conventional integral controller is used for all the studies demonstrated. The DC tie lines and AC-DC parallel tie-lines in an inter-connected power system give much better dynamic performance by bringing all the desired system variables to steady-state faster than in the existing AC tie-line inter-connected systems and quite smoothly. Eigenvalue analysis supports the results.<>