{"title":"旋转p-q-r参考系的瞬时功率理论","authors":"Hyosung Kim, H. Akagi","doi":"10.1109/PEDS.1999.794600","DOIUrl":null,"url":null,"abstract":"This paper proposed the rotating p-q-r reference frames where one instantaneous active power p, and two instantaneous reactive powers q/sub q/, q/sub r/ were defined in 3-phase 4-wire systems. The three power components are linearly independent, so that compensating for the two instantaneous reactive powers leads to control the two components of the current space vector independently. With the theory, this paper shows that the neutral current of a 3-phase 4-wire system can be eliminated by only compensating for the instantaneous reactive power using no energy storage element. Simulation results verify the theory very well.","PeriodicalId":254764,"journal":{"name":"Proceedings of the IEEE 1999 International Conference on Power Electronics and Drive Systems. PEDS'99 (Cat. No.99TH8475)","volume":"85-86 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-07-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"170","resultStr":"{\"title\":\"The instantaneous power theory on the rotating p-q-r reference frames\",\"authors\":\"Hyosung Kim, H. Akagi\",\"doi\":\"10.1109/PEDS.1999.794600\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposed the rotating p-q-r reference frames where one instantaneous active power p, and two instantaneous reactive powers q/sub q/, q/sub r/ were defined in 3-phase 4-wire systems. The three power components are linearly independent, so that compensating for the two instantaneous reactive powers leads to control the two components of the current space vector independently. With the theory, this paper shows that the neutral current of a 3-phase 4-wire system can be eliminated by only compensating for the instantaneous reactive power using no energy storage element. Simulation results verify the theory very well.\",\"PeriodicalId\":254764,\"journal\":{\"name\":\"Proceedings of the IEEE 1999 International Conference on Power Electronics and Drive Systems. PEDS'99 (Cat. No.99TH8475)\",\"volume\":\"85-86 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-07-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"170\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the IEEE 1999 International Conference on Power Electronics and Drive Systems. PEDS'99 (Cat. No.99TH8475)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEDS.1999.794600\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the IEEE 1999 International Conference on Power Electronics and Drive Systems. PEDS'99 (Cat. No.99TH8475)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEDS.1999.794600","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 170

摘要

本文提出了在三相四线制系统中定义一个瞬时有功功率p和两个瞬时无功功率q/sub q/、q/sub r/的旋转p-q-r参考系。三个功率分量是线性无关的,因此补偿两个瞬时无功功率可以独立控制电流空间矢量的两个分量。利用该理论,本文证明了三相四线制系统的中性电流可以通过不使用储能元件仅补偿瞬时无功功率来消除。仿真结果很好地验证了该理论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The instantaneous power theory on the rotating p-q-r reference frames
This paper proposed the rotating p-q-r reference frames where one instantaneous active power p, and two instantaneous reactive powers q/sub q/, q/sub r/ were defined in 3-phase 4-wire systems. The three power components are linearly independent, so that compensating for the two instantaneous reactive powers leads to control the two components of the current space vector independently. With the theory, this paper shows that the neutral current of a 3-phase 4-wire system can be eliminated by only compensating for the instantaneous reactive power using no energy storage element. Simulation results verify the theory very well.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信