Y. Sillapawicharn, Y. Kumsuwan
{"title":"基于双低通滤波器的电网电压暂降补偿器电压暂降检测","authors":"Y. Sillapawicharn, Y. Kumsuwan","doi":"10.1109/IEECON.2014.6925913","DOIUrl":null,"url":null,"abstract":"In this paper, dual low pass filter (DLPF)-based voltage sag detection for voltage sag compensator under distorted grid is proposed. The conventional synchronously rotating reference frame (CSRRF)-based voltage sag detection is the most famous voltage sag detection method in the past. However it has a huge disadvantage as a long delay of detection time. The detection time is moderately improved by the improved modified synchronously rotating reference frame (IMSRRF)-based voltage sag detection. This paper presents DLPF-based voltage sag detection which is providing the shortest detection time when comparing to other methods. The performance of proposed voltage sag detection is verified via computer simulations in various conditions.","PeriodicalId":306512,"journal":{"name":"2014 International Electrical Engineering Congress (iEECON)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2014-03-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Dual low pass filter-based voltage sag detection for voltage sag compensator under distorted grid voltages\",\"authors\":\"Y. Sillapawicharn, Y. Kumsuwan\",\"doi\":\"10.1109/IEECON.2014.6925913\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, dual low pass filter (DLPF)-based voltage sag detection for voltage sag compensator under distorted grid is proposed. The conventional synchronously rotating reference frame (CSRRF)-based voltage sag detection is the most famous voltage sag detection method in the past. However it has a huge disadvantage as a long delay of detection time. The detection time is moderately improved by the improved modified synchronously rotating reference frame (IMSRRF)-based voltage sag detection. This paper presents DLPF-based voltage sag detection which is providing the shortest detection time when comparing to other methods. The performance of proposed voltage sag detection is verified via computer simulations in various conditions.\",\"PeriodicalId\":306512,\"journal\":{\"name\":\"2014 International Electrical Engineering Congress (iEECON)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-03-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 International Electrical Engineering Congress (iEECON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IEECON.2014.6925913\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Electrical Engineering Congress (iEECON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEECON.2014.6925913","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

提出了一种基于双低通滤波器的电压暂降检测方法,用于畸变电网下电压暂降补偿器的电压暂降检测。传统的基于同步旋转参照系(CSRRF)的电压暂降检测方法是目前最著名的电压暂降检测方法。但是它的缺点是检测时间的延迟太长。采用改进的修正同步旋转参照系(IMSRRF)电压暂降检测方法,提高了检测时间。本文提出了基于dlpf的电压暂降检测方法,与其他方法相比,该方法的检测时间最短。通过计算机仿真,验证了所提出的电压暂降检测方法的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Dual low pass filter-based voltage sag detection for voltage sag compensator under distorted grid voltages
In this paper, dual low pass filter (DLPF)-based voltage sag detection for voltage sag compensator under distorted grid is proposed. The conventional synchronously rotating reference frame (CSRRF)-based voltage sag detection is the most famous voltage sag detection method in the past. However it has a huge disadvantage as a long delay of detection time. The detection time is moderately improved by the improved modified synchronously rotating reference frame (IMSRRF)-based voltage sag detection. This paper presents DLPF-based voltage sag detection which is providing the shortest detection time when comparing to other methods. The performance of proposed voltage sag detection is verified via computer simulations in various conditions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信