功率可扩展集群系统中低影响仪表代码的运行时能量适应

Hideaki Kimura, Takayuki Imada, M. Sato
{"title":"功率可扩展集群系统中低影响仪表代码的运行时能量适应","authors":"Hideaki Kimura, Takayuki Imada, M. Sato","doi":"10.1109/CCGRID.2010.70","DOIUrl":null,"url":null,"abstract":"Recently, improving the energy efficiency of high performance PC clusters has become important. In order to reduce the energy consumption of the microprocessor, many high performance microprocessors have a Dynamic Voltage and Frequency Scaling (DVFS) mechanism. This paper proposes a new DVFS method called the Code-Instrumented Runtime (CIRuntime) DVFS method, in which a combination of voltage and frequency, which is called a P-State, is managed in the instrumented code at runtime. The proposed CI-Runtime DVFS method achieves better energy saving than the Interrupt based Runtime DVFS method, since it selects the appropriate P-State in each defined region based on the characteristics of program execution. Moreover, the proposed CI-Runtime DVFS method is more useful than the Static DVFS method, since it does not acquire exhaustive profiles for each P-State. The method consists of two parts. In the first part of the proposed CI-Runtime DVFS method, the instrumented codes are inserted by defining regions that have almost the same characteristics. The instrumented code must be inserted at the appropriate point, because the performance of the application decreases greatly if the instrumented code is called too many times in a short period. A method for automatically defining regions is proposed in this paper. The second part of the proposed method is the energy adaptation algorithm which is used at runtime. Two types of DVFS control algorithms energy adaptation with estimated energy consumption and energy adaptation with only performance information, are compared. The proposed CIRuntime DVFS method was implemented on a power-scalable PC cluster. The results show that the proposed CI-Runtime with energy adaptation using estimated energy consumption could achieve an energy saving of 14.2% which is close to the optimal value, without obtaining exhaustive profiles for every available P-State setting.","PeriodicalId":444485,"journal":{"name":"2010 10th IEEE/ACM International Conference on Cluster, Cloud and Grid Computing","volume":"76 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-05-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"Runtime Energy Adaptation with Low-Impact Instrumented Code in a Power-Scalable Cluster System\",\"authors\":\"Hideaki Kimura, Takayuki Imada, M. Sato\",\"doi\":\"10.1109/CCGRID.2010.70\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Recently, improving the energy efficiency of high performance PC clusters has become important. In order to reduce the energy consumption of the microprocessor, many high performance microprocessors have a Dynamic Voltage and Frequency Scaling (DVFS) mechanism. This paper proposes a new DVFS method called the Code-Instrumented Runtime (CIRuntime) DVFS method, in which a combination of voltage and frequency, which is called a P-State, is managed in the instrumented code at runtime. The proposed CI-Runtime DVFS method achieves better energy saving than the Interrupt based Runtime DVFS method, since it selects the appropriate P-State in each defined region based on the characteristics of program execution. Moreover, the proposed CI-Runtime DVFS method is more useful than the Static DVFS method, since it does not acquire exhaustive profiles for each P-State. The method consists of two parts. In the first part of the proposed CI-Runtime DVFS method, the instrumented codes are inserted by defining regions that have almost the same characteristics. The instrumented code must be inserted at the appropriate point, because the performance of the application decreases greatly if the instrumented code is called too many times in a short period. A method for automatically defining regions is proposed in this paper. The second part of the proposed method is the energy adaptation algorithm which is used at runtime. Two types of DVFS control algorithms energy adaptation with estimated energy consumption and energy adaptation with only performance information, are compared. The proposed CIRuntime DVFS method was implemented on a power-scalable PC cluster. The results show that the proposed CI-Runtime with energy adaptation using estimated energy consumption could achieve an energy saving of 14.2% which is close to the optimal value, without obtaining exhaustive profiles for every available P-State setting.\",\"PeriodicalId\":444485,\"journal\":{\"name\":\"2010 10th IEEE/ACM International Conference on Cluster, Cloud and Grid Computing\",\"volume\":\"76 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-05-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 10th IEEE/ACM International Conference on Cluster, Cloud and Grid Computing\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CCGRID.2010.70\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 10th IEEE/ACM International Conference on Cluster, Cloud and Grid Computing","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CCGRID.2010.70","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

摘要

近年来,提高高性能PC集群的能源效率变得越来越重要。为了降低微处理器的能耗,许多高性能微处理器都采用了动态电压频率缩放(DVFS)机制。本文提出了一种新的DVFS方法,称为代码仪表化运行时(CIRuntime) DVFS方法,该方法在运行时在仪表化代码中管理称为p态的电压和频率组合。所提出的CI-Runtime DVFS方法根据程序执行的特点,在每个定义的区域中选择合适的P-State,比基于中断的Runtime DVFS方法节能。此外,所提出的CI-Runtime DVFS方法比静态DVFS方法更有用,因为它不获取每个P-State的详尽配置文件。该方法由两部分组成。在提出的CI-Runtime DVFS方法的第一部分中,通过定义具有几乎相同特征的区域来插入检测代码。插装代码必须在适当的位置插入,因为如果在短时间内多次调用插装代码,应用程序的性能将大大降低。提出了一种自动定义区域的方法。该方法的第二部分是在运行时使用的能量自适应算法。比较了带预估能耗的能量自适应和仅带性能信息的能量自适应两种DVFS控制算法。在功率可扩展的PC集群上实现了所提出的运行时DVFS方法。结果表明,在不需要获得所有可用P-State设置的详尽概况的情况下,基于估计能耗的能量自适应CI-Runtime可以实现接近最优值的14.2%的节能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Runtime Energy Adaptation with Low-Impact Instrumented Code in a Power-Scalable Cluster System
Recently, improving the energy efficiency of high performance PC clusters has become important. In order to reduce the energy consumption of the microprocessor, many high performance microprocessors have a Dynamic Voltage and Frequency Scaling (DVFS) mechanism. This paper proposes a new DVFS method called the Code-Instrumented Runtime (CIRuntime) DVFS method, in which a combination of voltage and frequency, which is called a P-State, is managed in the instrumented code at runtime. The proposed CI-Runtime DVFS method achieves better energy saving than the Interrupt based Runtime DVFS method, since it selects the appropriate P-State in each defined region based on the characteristics of program execution. Moreover, the proposed CI-Runtime DVFS method is more useful than the Static DVFS method, since it does not acquire exhaustive profiles for each P-State. The method consists of two parts. In the first part of the proposed CI-Runtime DVFS method, the instrumented codes are inserted by defining regions that have almost the same characteristics. The instrumented code must be inserted at the appropriate point, because the performance of the application decreases greatly if the instrumented code is called too many times in a short period. A method for automatically defining regions is proposed in this paper. The second part of the proposed method is the energy adaptation algorithm which is used at runtime. Two types of DVFS control algorithms energy adaptation with estimated energy consumption and energy adaptation with only performance information, are compared. The proposed CIRuntime DVFS method was implemented on a power-scalable PC cluster. The results show that the proposed CI-Runtime with energy adaptation using estimated energy consumption could achieve an energy saving of 14.2% which is close to the optimal value, without obtaining exhaustive profiles for every available P-State setting.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信