使用Volt-sec。提高了后向电磁自传感的低速范围和抗干扰能力

Yukai Wang, R. Lorenz
{"title":"使用Volt-sec。提高了后向电磁自传感的低速范围和抗干扰能力","authors":"Yukai Wang, R. Lorenz","doi":"10.1109/EPE.2016.7695488","DOIUrl":null,"url":null,"abstract":"This paper introduces usage of Volt-sec. sensing in back-EMF-based self-sensing (sensorless) induction machine drives. In practice, both inverter nonlinearity and dc bus voltage affect back-EMF estimation accuracy, and therefore self-sensing performance. A real-time Volt-sec. sensing scheme to measure the terminal Volt-sec. vector for each switching period is introduced in the paper. The measured Volt-sec. information can be used in the back-EMF state filter such that the effects from inverter nonlinearity and dc bus voltage measurement errors are mitigated. The resulting extended low speed range and enhanced disturbance rejection capability are quantified via experimental evaluation.","PeriodicalId":119358,"journal":{"name":"2016 18th European Conference on Power Electronics and Applications (EPE'16 ECCE Europe)","volume":"23 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Using Volt-sec. sensing to extend the low speed range and the disturbance rejection capability of back-EMF-based self-sensing\",\"authors\":\"Yukai Wang, R. Lorenz\",\"doi\":\"10.1109/EPE.2016.7695488\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper introduces usage of Volt-sec. sensing in back-EMF-based self-sensing (sensorless) induction machine drives. In practice, both inverter nonlinearity and dc bus voltage affect back-EMF estimation accuracy, and therefore self-sensing performance. A real-time Volt-sec. sensing scheme to measure the terminal Volt-sec. vector for each switching period is introduced in the paper. The measured Volt-sec. information can be used in the back-EMF state filter such that the effects from inverter nonlinearity and dc bus voltage measurement errors are mitigated. The resulting extended low speed range and enhanced disturbance rejection capability are quantified via experimental evaluation.\",\"PeriodicalId\":119358,\"journal\":{\"name\":\"2016 18th European Conference on Power Electronics and Applications (EPE'16 ECCE Europe)\",\"volume\":\"23 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 18th European Conference on Power Electronics and Applications (EPE'16 ECCE Europe)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPE.2016.7695488\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 18th European Conference on Power Electronics and Applications (EPE'16 ECCE Europe)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPE.2016.7695488","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

本文介绍了伏特秒的用法。基于反向电动势的自传感(无传感器)感应电机驱动中的传感。在实际应用中,逆变器的非线性和直流母线电压都会影响反电动势估计的精度,从而影响自感知性能。实时伏特秒。测量终端伏特秒的传感方案。文中介绍了各切换周期的矢量。测量的伏秒。信息可以用于反电动势状态滤波器,从而减轻逆变器非线性和直流母线电压测量误差的影响。由此产生的低速范围的扩大和抗干扰能力的增强通过实验评估量化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Using Volt-sec. sensing to extend the low speed range and the disturbance rejection capability of back-EMF-based self-sensing
This paper introduces usage of Volt-sec. sensing in back-EMF-based self-sensing (sensorless) induction machine drives. In practice, both inverter nonlinearity and dc bus voltage affect back-EMF estimation accuracy, and therefore self-sensing performance. A real-time Volt-sec. sensing scheme to measure the terminal Volt-sec. vector for each switching period is introduced in the paper. The measured Volt-sec. information can be used in the back-EMF state filter such that the effects from inverter nonlinearity and dc bus voltage measurement errors are mitigated. The resulting extended low speed range and enhanced disturbance rejection capability are quantified via experimental evaluation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信