{"title":"fes辅助步态关节耦合矫形器的设计","authors":"R. Farris, Hugo A. Quintero, T. Withrow, M. Goldfarb","doi":"10.1109/ICORR.2009.5209623","DOIUrl":null,"url":null,"abstract":"A hybrid functional electrical stimulation (FES)/orthosis system is being developed which combines two channels of (surface-electrode-based) electrical stimulation with a computer-controlled orthosis for the purpose of restoring gait to spinal cord injured (SCI) individuals (albeit with a stability aid, such as a walker). The orthosis is an energetically passive, controllable device which 1) unidirectionally couples hip to knee flexion; 2) aids hip and knee flexion with a spring assist; and 3) incorporates sensors and modulated friction brakes, which are used in conjunction with electrical stimulation for the feedback control of joint (and therefore limb) trajectories. This paper describes the hybrid FES approach and the design of the joint coupled orthosis. Preliminary experiments are presented which test the joint coupling concept and assess the extent of quadriceps fatigue imposed by the bias spring and joint coupling.","PeriodicalId":189213,"journal":{"name":"2009 IEEE International Conference on Rehabilitation Robotics","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-06-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"25","resultStr":"{\"title\":\"Design of a joint-coupled orthosis for FES-aided gait\",\"authors\":\"R. Farris, Hugo A. Quintero, T. Withrow, M. Goldfarb\",\"doi\":\"10.1109/ICORR.2009.5209623\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A hybrid functional electrical stimulation (FES)/orthosis system is being developed which combines two channels of (surface-electrode-based) electrical stimulation with a computer-controlled orthosis for the purpose of restoring gait to spinal cord injured (SCI) individuals (albeit with a stability aid, such as a walker). The orthosis is an energetically passive, controllable device which 1) unidirectionally couples hip to knee flexion; 2) aids hip and knee flexion with a spring assist; and 3) incorporates sensors and modulated friction brakes, which are used in conjunction with electrical stimulation for the feedback control of joint (and therefore limb) trajectories. This paper describes the hybrid FES approach and the design of the joint coupled orthosis. Preliminary experiments are presented which test the joint coupling concept and assess the extent of quadriceps fatigue imposed by the bias spring and joint coupling.\",\"PeriodicalId\":189213,\"journal\":{\"name\":\"2009 IEEE International Conference on Rehabilitation Robotics\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-06-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"25\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 IEEE International Conference on Rehabilitation Robotics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICORR.2009.5209623\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 IEEE International Conference on Rehabilitation Robotics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICORR.2009.5209623","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 25

摘要

一种混合功能电刺激(FES)/矫形器系统正在开发中,它结合了两种通道(基于表面电极的)电刺激和计算机控制的矫形器,目的是恢复脊髓损伤(SCI)个体的步态(尽管需要稳定辅助,如助行器)。矫形器是一种能量被动、可控的装置,1)单向耦合髋关节和膝关节屈曲;2)通过弹簧辅助辅助髋关节和膝关节屈曲;3)集成了传感器和调制摩擦制动器,它们与电刺激一起用于关节(因此也是肢体)轨迹的反馈控制。本文介绍了混合FES方法和关节耦合矫形器的设计。提出了验证关节耦合概念的初步实验,评估了偏置弹簧和关节耦合对股四头肌的疲劳程度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design of a joint-coupled orthosis for FES-aided gait
A hybrid functional electrical stimulation (FES)/orthosis system is being developed which combines two channels of (surface-electrode-based) electrical stimulation with a computer-controlled orthosis for the purpose of restoring gait to spinal cord injured (SCI) individuals (albeit with a stability aid, such as a walker). The orthosis is an energetically passive, controllable device which 1) unidirectionally couples hip to knee flexion; 2) aids hip and knee flexion with a spring assist; and 3) incorporates sensors and modulated friction brakes, which are used in conjunction with electrical stimulation for the feedback control of joint (and therefore limb) trajectories. This paper describes the hybrid FES approach and the design of the joint coupled orthosis. Preliminary experiments are presented which test the joint coupling concept and assess the extent of quadriceps fatigue imposed by the bias spring and joint coupling.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信