耦合层厚度对空心轴超声检测的影响

Dong Cai, Cheng Zou, Zhenguo Sun, Qingxiang Zhou, Ye Fu, Guangkai Li
{"title":"耦合层厚度对空心轴超声检测的影响","authors":"Dong Cai, Cheng Zou, Zhenguo Sun, Qingxiang Zhou, Ye Fu, Guangkai Li","doi":"10.1109/ICCAR.2015.7166019","DOIUrl":null,"url":null,"abstract":"The thickness of coupling layer between the hollow axle inner wall and the probe wedge may vary during actual ultrasonic inspection. To study the influence of coupling layer thickness on the hollow ultrasonic inspection, the simulation models with different probe angles and different thicknesses of coupling layer were established with COMSOL Multiphysics. Flaw echoes from 38° and 45° probes under various coupling thickness were calculated and analyzed in details. A special experimental system was designed to validate the simulation results. Both simulation and experiment show that the coupling thickness variation may impact the reliability of ultrasonic testing results when the coupling thickness is less than 0.9mm.","PeriodicalId":422587,"journal":{"name":"2015 International Conference on Control, Automation and Robotics","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"The influence of coupling layer thickness on hollow axles ultrasonic testing\",\"authors\":\"Dong Cai, Cheng Zou, Zhenguo Sun, Qingxiang Zhou, Ye Fu, Guangkai Li\",\"doi\":\"10.1109/ICCAR.2015.7166019\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The thickness of coupling layer between the hollow axle inner wall and the probe wedge may vary during actual ultrasonic inspection. To study the influence of coupling layer thickness on the hollow ultrasonic inspection, the simulation models with different probe angles and different thicknesses of coupling layer were established with COMSOL Multiphysics. Flaw echoes from 38° and 45° probes under various coupling thickness were calculated and analyzed in details. A special experimental system was designed to validate the simulation results. Both simulation and experiment show that the coupling thickness variation may impact the reliability of ultrasonic testing results when the coupling thickness is less than 0.9mm.\",\"PeriodicalId\":422587,\"journal\":{\"name\":\"2015 International Conference on Control, Automation and Robotics\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-05-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Conference on Control, Automation and Robotics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICCAR.2015.7166019\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Control, Automation and Robotics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCAR.2015.7166019","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

在实际超声检测过程中,空心轴内壁与探头楔之间的耦合层厚度可能会发生变化。为了研究耦合层厚度对空心超声检测的影响,利用COMSOL Multiphysics软件建立了不同探头角度和不同耦合层厚度的仿真模型。对不同耦合厚度下38°和45°探头的缺陷回波进行了详细的计算和分析。设计了一个专门的实验系统来验证仿真结果。仿真和实验均表明,当耦合厚度小于0.9mm时,耦合厚度的变化会影响超声检测结果的可靠性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The influence of coupling layer thickness on hollow axles ultrasonic testing
The thickness of coupling layer between the hollow axle inner wall and the probe wedge may vary during actual ultrasonic inspection. To study the influence of coupling layer thickness on the hollow ultrasonic inspection, the simulation models with different probe angles and different thicknesses of coupling layer were established with COMSOL Multiphysics. Flaw echoes from 38° and 45° probes under various coupling thickness were calculated and analyzed in details. A special experimental system was designed to validate the simulation results. Both simulation and experiment show that the coupling thickness variation may impact the reliability of ultrasonic testing results when the coupling thickness is less than 0.9mm.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信