钢纤维对平板自密实混凝土冲剪强度的影响

J. R. Al-Feel, Asmahan Mahmood Sultan
{"title":"钢纤维对平板自密实混凝土冲剪强度的影响","authors":"J. R. Al-Feel, Asmahan Mahmood Sultan","doi":"10.33899/rengj.2014.101499","DOIUrl":null,"url":null,"abstract":"Flat slabs are the slab without beam so it save level of the floor. The punching shear caused failure around the column area under applied load on the column, to reduce this failure shear reinforcement were used but it is not easy practically especially for low slab thickness, it can be used steel fibres in the concrete mix to increase the punching shear strength. The aim of the research to study the punching shear of flat slab of self compacting concrete ,this type of concrete used widely because it is environmental friendly. The main parameters are the reinforcement of the slab, two percent were taken with different volume percent of steel fibre (0,0.4,0.8,1.2)%.The main results obtained that the punching shear strength increased with the volume percent of fiber and steel reinforcement, it increased about 27.95% , 21.4% for slabs with reinforcement ratio =1.4%, =1.8% respectively for 1.2% fibre, and the energy absorption increased about 107% for slab with 1.2% fibre and =1.8% compared with slab without fibre. The results show also increased in ductility as the fibre content increase and the failure perimeter of the slabs is approximately circular shape and the failure perimeter increase as the fibre content increased. :ملتسأ 28 – 6 2013 :لبق 13 – 10 2013 Al-Rafidain Engineering Vol.22 No. 4 May 2014","PeriodicalId":339890,"journal":{"name":"AL Rafdain Engineering Journal","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Influence of steel fibres on punching shear strength of flat slabs self compacting concrete\",\"authors\":\"J. R. Al-Feel, Asmahan Mahmood Sultan\",\"doi\":\"10.33899/rengj.2014.101499\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Flat slabs are the slab without beam so it save level of the floor. The punching shear caused failure around the column area under applied load on the column, to reduce this failure shear reinforcement were used but it is not easy practically especially for low slab thickness, it can be used steel fibres in the concrete mix to increase the punching shear strength. The aim of the research to study the punching shear of flat slab of self compacting concrete ,this type of concrete used widely because it is environmental friendly. The main parameters are the reinforcement of the slab, two percent were taken with different volume percent of steel fibre (0,0.4,0.8,1.2)%.The main results obtained that the punching shear strength increased with the volume percent of fiber and steel reinforcement, it increased about 27.95% , 21.4% for slabs with reinforcement ratio =1.4%, =1.8% respectively for 1.2% fibre, and the energy absorption increased about 107% for slab with 1.2% fibre and =1.8% compared with slab without fibre. The results show also increased in ductility as the fibre content increase and the failure perimeter of the slabs is approximately circular shape and the failure perimeter increase as the fibre content increased. :ملتسأ 28 – 6 2013 :لبق 13 – 10 2013 Al-Rafidain Engineering Vol.22 No. 4 May 2014\",\"PeriodicalId\":339890,\"journal\":{\"name\":\"AL Rafdain Engineering Journal\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-09-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"AL Rafdain Engineering Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.33899/rengj.2014.101499\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"AL Rafdain Engineering Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33899/rengj.2014.101499","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

平板是没有梁的板,所以它节省了地板的水平。在柱受荷载作用下,冲剪会引起柱周围区域的破坏,为了减少这种破坏,通常采用剪力钢筋,但在实际应用中并不容易,特别是对于低板厚度的混凝土,可以在混凝土配合比中加入钢纤维来增加冲剪强度。本研究的目的是研究自密实混凝土平板的冲剪性能,自密实混凝土因其对环境友好而得到广泛应用。主要参数为板的配筋率,采用不同体积百分比的钢纤维(0,0.4,0.8,1.2)%。研究结果表明:随着纤维和钢筋体积百分比的增加,冲剪强度增大,钢筋体积百分比为1.4%和1.2%的板的冲剪强度分别增大27.95%和21.4%,纤维体积百分比为1.4%和1.8%的板的冲剪强度比不含纤维的板的冲剪强度分别增大107%和1.8%。结果表明,随着纤维含量的增加,延性也有所增加,板的破坏周长近似圆形,破坏周长随着纤维含量的增加而增加。:ملتسأ 28 - 6 2013:لبق 13 - 10 2013 Al-Rafidain Engineering Vol.22 No. 4 2014年5月
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Influence of steel fibres on punching shear strength of flat slabs self compacting concrete
Flat slabs are the slab without beam so it save level of the floor. The punching shear caused failure around the column area under applied load on the column, to reduce this failure shear reinforcement were used but it is not easy practically especially for low slab thickness, it can be used steel fibres in the concrete mix to increase the punching shear strength. The aim of the research to study the punching shear of flat slab of self compacting concrete ,this type of concrete used widely because it is environmental friendly. The main parameters are the reinforcement of the slab, two percent were taken with different volume percent of steel fibre (0,0.4,0.8,1.2)%.The main results obtained that the punching shear strength increased with the volume percent of fiber and steel reinforcement, it increased about 27.95% , 21.4% for slabs with reinforcement ratio =1.4%, =1.8% respectively for 1.2% fibre, and the energy absorption increased about 107% for slab with 1.2% fibre and =1.8% compared with slab without fibre. The results show also increased in ductility as the fibre content increase and the failure perimeter of the slabs is approximately circular shape and the failure perimeter increase as the fibre content increased. :ملتسأ 28 – 6 2013 :لبق 13 – 10 2013 Al-Rafidain Engineering Vol.22 No. 4 May 2014
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信