铁路运行产生的谐波

D. Vujatovic, Qinping Zhang
{"title":"铁路运行产生的谐波","authors":"D. Vujatovic, Qinping Zhang","doi":"10.1109/PES.2006.1709352","DOIUrl":null,"url":null,"abstract":"This paper reports harmonics generated while typical high-speed railways are under operation. The solution in reducing harmonics by the use of installation of power electronic compensators, especially static VAR compensator (SVC), in the railway system during the procedure of railway infrastructure upgrading may not be a very easy solution. Discussions are given and better method and approach are proposed. In order to find effective solutions to balance the main drawback of SVC compensators, such as the harmonic currents injected into the railway catenary due to their highly non-linear characteristics. Analysis of a large volume of data, which had been collected in a practical high-speed railway project has been carried out to study the harmonics content. Negative consequences of SVC to the both railway and grid system could be minimized by the discussed approach","PeriodicalId":267582,"journal":{"name":"2006 IEEE Power Engineering Society General Meeting","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Harmonics generated from railway operation\",\"authors\":\"D. Vujatovic, Qinping Zhang\",\"doi\":\"10.1109/PES.2006.1709352\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper reports harmonics generated while typical high-speed railways are under operation. The solution in reducing harmonics by the use of installation of power electronic compensators, especially static VAR compensator (SVC), in the railway system during the procedure of railway infrastructure upgrading may not be a very easy solution. Discussions are given and better method and approach are proposed. In order to find effective solutions to balance the main drawback of SVC compensators, such as the harmonic currents injected into the railway catenary due to their highly non-linear characteristics. Analysis of a large volume of data, which had been collected in a practical high-speed railway project has been carried out to study the harmonics content. Negative consequences of SVC to the both railway and grid system could be minimized by the discussed approach\",\"PeriodicalId\":267582,\"journal\":{\"name\":\"2006 IEEE Power Engineering Society General Meeting\",\"volume\":\"29 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-10-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 IEEE Power Engineering Society General Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PES.2006.1709352\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE Power Engineering Society General Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PES.2006.1709352","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

本文报道了典型高速铁路运行过程中产生的谐波。在铁路基础设施升级改造过程中,在铁路系统中安装电力电子补偿器,特别是静态无功补偿器(SVC)来降低谐波可能不是一个很容易解决的问题。并进行了讨论,提出了更好的方法和途径。为了找到有效的解决方案来平衡SVC补偿器的主要缺点,如谐波电流注入铁路接触网由于其高度非线性的特性。通过对实际高速铁路工程中采集的大量数据进行分析,对谐波含量进行了研究。所讨论的方法可以最大限度地减少SVC对铁路和电网系统的负面影响
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Harmonics generated from railway operation
This paper reports harmonics generated while typical high-speed railways are under operation. The solution in reducing harmonics by the use of installation of power electronic compensators, especially static VAR compensator (SVC), in the railway system during the procedure of railway infrastructure upgrading may not be a very easy solution. Discussions are given and better method and approach are proposed. In order to find effective solutions to balance the main drawback of SVC compensators, such as the harmonic currents injected into the railway catenary due to their highly non-linear characteristics. Analysis of a large volume of data, which had been collected in a practical high-speed railway project has been carried out to study the harmonics content. Negative consequences of SVC to the both railway and grid system could be minimized by the discussed approach
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信